solaris - A+CLASS 2, 3-Lamp T8, T5(HO) Direct/Indirect Distribution Project Information

Features • • • • • • • • • • • • •

A+CLASS™ energy management system compatible A+CLASS™ GEN/ A/V lighting compatible LEED and CHPS compatible Direct/Indirect distribution T8 lamps standard. For T5 or T5HO, contact factory Heavy 20-gauge steel construction provides excellent housing rigidity Adjustable 48" (CM48) aircraft cable yoke hanger with vertical and horizontal balancing Die cast couplers and end caps ensure straight rows with no light leak Fixed louver stays in housing, even if fixture is struck or damaged RAL colors available A+CLASS™ system includes lighting controls, switches, and low voltage wiring See APCS submittal for more detail Limited options are available on Alera Express

Project Name

Type

Catalog No.

Date

A+CLASS

Mounting

A+CLASS™ compatible. Can be installed as part of A+CLASS™ classroom-in-a-box installation. A+CLASS™ electronic ballast must be program rapid start (EP). Electronic Dimming (ED) requires 0-10V ballast. 347V not available.

CM– Solaris utilizes a unique hanging system that makes vertical and horizontal adjustment effortless. The aircraft cable assembly is totally adjustable. Precise horizontal balancing is accomplished by sliding a cable gripper along a metal yoke on each end. The cable gripper is simply turned and locked into place once the fixture is leveled. The double hanging system allows the suspension points to be placed on 48" centers for quick and easy installation. Rigid stems are available as options.

Construction – 4', 8', and 12' housings – Reinforcement provided to consume maximum rigidity across the entire housing. – Diecast aluminum end caps provide zero tolerance alignment between fixtures, resulting in consistently straight rows with no snaking. – Upper reflectors are constructed of specular anodized aluminum for precise upward distribution. – Relamped from above

Finish The housing is finished with a baked powder coat matte white finish as standard. Diecast end caps and intermediate couplers are painted to match the housing. Hanging stems and canopies are painted white. Cable fittings are standard chrome.

shielding Louvers attach securely to the housing from the top, eliminating any chance of loosening or falling from the fixture.

Shape and Dimensions

– Constructed of semi-specular anodized aluminum, the eleven-cell louver (LD) measures 1½" high and provides maximum efficiency and a glare-free environment. The aluminum finish will remain dust and fingerprint free.

2 3/4" 91/2"

Ordering Information

SLS





Model SLS Solaris High Performance Lighting To order A+CLASS™ controls: see page APCS.

Distribution – In GEN (general) lighting mode, the Solaris distribution provides direct/indirect lighting 80% up, 20% down. – Our (CLC) Center Lamp Cover directs 100% of the center lamp light down, when the lighting is switched to A/V mode.

Labels and Electrical – All luminaires are built to UL1598 Standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. – Quick-connect plugs standard.

Name: Test #: Efficiency: LER:

SLS-3T8-2UD-CLC ITL 63074 89.5% 82

Example: SLS-24-3T8-CLC-LD-EPG/EPA277-MW



LAMP TYPE AND PROFILE 2T8 Two T8 Lamps5 3T8 Three T8 Lamps 4 2T5 Two T5 Lamps5 3T5 Three T5 Lamps 4

row length 4' Single 8' Single 12' Single Indicate row length over 12' in 4' increments Note: Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory. 4 8 12 —

WM– Mounts directly to and is flush with the wall.

Distribution CLC Center Lamp Cover A/V Mode (3-Lamp only)

— CM MOUNTING Method CM Adjustable Aircraft Cable Mount

— LD — Shielding LD Low Iridescent SemiSpecular Louver (Std.)

Adjustable Cable length 48 48" 96 96" Other lengths available on request.

— Voltage U 120V-277V 120 120V 277 277V

— FInish MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors.

Gen/AV Ballast COntrol EPG/EPA Programmed Start - GEN, Programmed Start - A/V4, 5 EDG/EPA 0-10V Dimming - GEN, Programmed Start - A/V 3, 4 EDG/EDA Dimming - GEN, Dimming - A/V 3, 4, 5 EPG/EDA Programmed Start - GEN, Dimming - A/V 3, 4 ESDGA Step Dimming: 100% - GEN, 50% - A/V2

Options EL One Emergency Battery Pack1, 2 GLR Fast Blow Fuse GMF Slow Blow Fuse TBAR T-Bar Mounting

Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). Not available with all configurations; some limitations apply. Contact factory for details. 3 Requires dimming ballast. 4 Standard 3-lamp is dual circuit inboard/outboard. 5 Standard 2-lamp is dual circuit left/right. 1

2

Page 1/2 Rev. 07/31/13

US Patent #8,436,542

© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

curves / SLS - APCS

solaris - A+CLASS 2, 3-Lamp T8, T5(HO) Direct/Indirect Distribution Cross section

A+CLASS SLS-3T8

SLS-3T8 A/V Mode

SLS-3T8 GEN mode

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

SLS-3T8-2UD-CLC-LDEU-MW4-IBOB Solaris Architectural Curve 9" × 48" 3 LAMP WITH 1 × 11 CELL SEMISPECULAR LOUVER B332I120RH-A 0.88 Two 32W T8 FO32-835 2950 89 0º = 21  90º = 25 0º = 1.2  90º = 1.25 Length: 3.80 Width: 0.37 Height: 0.00

SLS-3T8 GEN mode

45 55 65 75 85

0.0

4391 2951 969 105 157

22.5

4498 3379 1809 211 235

45.0

4546 3796 3230 264 235 RCR

Luminaire

Angle

Luminaire Data Test ITL63074 Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) RC RW 1 2 3 4 5 6 7 8 9 10

70 85 78 71 65 60 55 51 48 44 41

80 50 30 82 78 72 67 64 58 57 50 50 44 45 38 41 34 37 31 34 27 31 25

10 76 63 53 45 39 34 29 26 23 21

70 77 70 64 59 54 50 46 43 40 37

70 50 30 74 71 65 61 58 53 51 46 46 40 41 35 37 32 34 28 31 25 28 23

10 69 57 49 42 36 31 27 24 22 19

50 59 53 47 42 38 34 31 28 26 24

50 30 58 50 43 38 33 30 26 24 21 19

10 56 47 40 35 30 26 23 21 18 17

Indoor Candela Plot 0 0 27 24 21 18 16 14 13 11 10 9

180˚

165˚

150˚

135˚

1000

120˚ 500

105˚

90˚

75˚

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 656 1049 1661 1787 1033 1610 2699 3497 5283

11.1 17.8 28.2 30.3 17.5 27.3 45.7 59.3 89.5

12.4 19.9 31.4 33.8 19.6 30.5 51.1 66.2 100.0

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

500 60˚

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

89.5% 82 Yes-VDT Normal Use $2.93 based on 3000 hrs. and $0.08 per KWH

1000 0˚ 15˚ LEGEND: 0-deg: 45-deg: 90-deg:

30˚

45˚

Test Date 9/22/09

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

SLS-3T8-LD-CLC-LDEU-MW4-IBOB Solaris Architectural Curve 9" × 48" 2 LAMP WITH 1 × 11 CELL SEMISPECULAR LOUVER Universal B132IUNVHP-B 0.88 One 32W T8 FO32/835 2950 29.2 Suspended 0º = 21  90º = 35 0º = 1.24  90º = 1.18 Length: 3.80 Width: 0.37 Height: 0.00

SLS-3T8 A/V Mode

45 55 65 75 85

0.0

4864 3343 1050 79 0

22.5 4758 3724 1583 132 0

45.0

5260 4438 1179 290 0 RCR

Luminaire

Angle

Luminaire Data Test ITL63075 Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) RC RW 1 2 3 4 5 6 7 8 9 10

70 68 63 58 54 50 46 43 40 37 35

80 50 30 66 64 59 55 53 48 47 43 43 38 39 34 35 30 32 27 30 25 27 23

10 62 53 45 39 34 30 27 24 22 20

70 66 61 57 52 48 45 42 39 36 34

70 50 30 64 62 58 54 52 48 46 42 42 37 38 33 35 30 32 27 29 25 27 23

10 61 52 45 39 34 30 27 24 22 20

50 62 55 50 45 41 37 34 31 29 26

50 30 60 53 47 41 37 33 30 27 25 22

10 59 51 44 38 34 30 27 24 22 20

Indoor Candela Plot 0 0 54 47 41 36 32 28 25 23 20 19

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 631 1019 1694 1792 1 3 5 7 1798

21.4 34.5 57.4 60.7 0.0 0.1 0.2 0.2 61.0

35.1 56.6 94.2 99.6 0.1 0.1 0.3 0.4 100.0

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

61.0% 55 Yes-VDT Normal Use $4.36 based on 3000 hrs. and $0.08 per KWH

90˚

75˚ 300 60˚

600 45˚

900 0˚ LEGEND: 0-deg: 45-deg: 90-deg:

15˚

30˚

Test Date 9/21/2009

Page 2/2 Rev. 07/31/13

US Patent #8,436,542

© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com