Avalon Cable Mount 2, 3, 4-Lamp T8, Direct/Indirect Distribution Project Information Project Name
Type
Catalog No.
Date
binder.
Construction —4', 8' and 12' fixture housing lengths
Shielding —Versatile shielding options permit a variety of treatments for the side openings.
—Extrusion is reinforced by heavy gauge steel structural endplate supports.
Features • Maximum aesthetic options with eight different shielding choices including standard or custom ScreenArt™ • Direct/Indirect Luminaire • Extruded aluminum housing • Controls compatible • Choice of sculpted or flat end caps • Adjustable cable hanger system allows quick and easy field installation without tools • Quick connect wiring for simple electrical connections • Wall mount available
—Fixtures in rows are joined without the need for tools for either mechanical or electrical connections.
—Perforated steel pinhole panels
—The simple, snap-together post and clip connector holds with over 300 pounds of force, ensuring secure, straight rows.
—Solid steel side panels for uplight only
—ScreenArt™ silkscreened acrylic panels for a luminous body The seam between shielding panels is concealed by an extruded aluminum mullion finished to match the housing to ensure a clean, finished appearance in long, continuous row applications.
—Slotted, specular aluminum reflector controls the downlight component. —For a higher percentage of downlight, the “DRF” specular aluminum reflector may be specified.
Mounting The Avalon is designed for ceiling suspension with field adjustable cable as standard.
—Center-mounted ballasts preclude the need for ballast counterbalancing mechanisms.
Labels and Electrical —UL 1598 or CSA
Finish Exterior fixture finish is powder coat with matte white as standard. All painted parts are treated with a five-stage phosphate bonding process before painting. For other color selections, refer to MTX-1 in the Options section of the Alera
—Prewired with T8 electronic ballasts —Quick connect plugs standard —Damp label available on most models
Shape and Dimensions 31/4" 10½"
Ordering Information
AVL
—
Model AVL Avalon
Row length 4 4' Single 8 8' Single — Indicate row length over 8' in 4' increments Note: Rows over 8' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory.
—
Example: AVL-20-2T8-UD-CM48-MPO-EU-M
—
LAMP TYPE AND PROFILE 2T8 Two T8 Lamps 3T8 Three T8 Lamps 4T8 Four T8 Lamps
—
—
MOUNTING CM Adjustable Aircraft Cable Mount PMB Pendant Mount See HGR-1 for other hanging methods.
Distribution UD Uplight and Downlight U Uplight (MSP shielding only)
Shielding MPO Metal Perforated with Overlay MPF Metal Perforated with No Overlay MSP Metal Side Panel (Includes uplight only reflector)
Adjustable Cable length 48 48" 96 96" Other lengths available on request.
Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). Not available with all configurations. Some limitations apply. Contact factory for details. 3 One extra feed drop per EMC. (For through wiring, contact factory.) 1 2
—
— U 120 277 347
Ballast E Electronic, Instant Start ED Electronic, Dimming (Must specify) Unless specified, Alera will use fewest ballasts possible.
Voltage 120V-277V 120V 277V 347V
Finish MW Matte White ZT ZET Metallic Silver
— Options DC Dust Cover (N/A T5HO) DRF Downlight Reflector HRF High Efficiency Reflector SCE Sculpted End Cap LR Left/Right Switching (2-Lamp only) IBOB Inboard/Outboard Switching (3-Lamp only) EL One Emergency Battery Pack1, 2 EMC One Emergency Circuit2, 3 NL Night Light Circuit 2, 3 GLR Fast Blow Fuse GMF Slow Blow Fuse TBAR T-Bar Mounting CSA UL listed or CSA certified for Canada DL Damp Label (Available on most models)
Page 1/3 Rev. 09/29/09 © 2009 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1580 / Website www.aleralighting.com
Curves / AVL CM
Avalon Cable Mount 2, 3, 4-Lamp T8, Direct/Indirect Distribution Cross section
31/4"
31/4"
10½" AVL2T8
31/4"
10½" AVL3T8
10½" AVL4T8
Photometric Data
Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet
AVL2T8UD-OLSB-EB8-4 Avalon Architectural Curve 10" × 49" 2-LAMP WITH OVAL LINEAR SLOT LENS, BLACK SCREEN B232I120RH 0.88 F32T8 2900 59 Pendant 0º = 90 90º = 90 0º = 1.28 90º = 1.32 Length: 4.08 Width: 0.47 Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0 112 117 110 111 105 108 101 93 82 87 65 0
112 117 110 111 114 108 101 106 98 108 129 193
112 117 117 111 114 117 112 133 148 174 226 386
112 117 117 119 122 127 135 146 181 217 291 515
112 117 125 119 122 127 146 159 181 239 323 580
Zonal Lumen Summary Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 16 27 49 72 1411 2271 3704 4488 4560
0.3 0.5 0.8 1.2 24.3 39.2 63.9 77.4 78.6
0.4 0.6 1.1 1.6 30.9 49.8 81.2 98.4 100.0
RCR
Luminaire
Angle
Luminaire Data Test 11605
RC RW 1 2 3 4 5 6 7 8 9 10
70 68 62 57 52 47 43 40 37 34 31
80 50 30 65 62 57 52 50 45 44 38 39 33 35 29 31 25 28 22 25 20 23 18
10 60 49 40 34 29 24 21 18 16 14
70 58 53 48 44 40 37 34 31 29 27
70 50 30 56 54 49 45 43 39 38 33 33 29 30 25 27 22 24 19 22 17 20 15
10 52 42 35 29 25 21 18 16 14 12
50 39 34 30 26 23 21 19 17 15 14
50 30 37 32 27 23 20 18 15 14 12 11
10 36 30 25 21 18 15 13 11 10 9
Indoor Candela Plot 0 0 1 1 1 1 0 0 0 0 0 0
180
165
150
135
1400
120 700 105
90
75
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
700 60
Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
78.6% 68 Yes-VDT Intensive Use $3.53 based on 3000 hrs. and $0.08 per KWH
1400 0
0.0
15
30 Horiz 0-180
45.0
45
90.0
Test Date 11/18/96
Photometric Data
Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet
AVL2T8UD-OLSWEB8-4 Avalon Architectural Curve 10" × 49" 2-LAMP WITH OVAL LINEAR SLOT LENS, WHITE SCREEN B232I120RH 0.88 F32T8 2900 60 Pendant 0º = 90 90º = 90 0º = 1.28 90º = 1.30 Length: 4.08 Width: 0.47 Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
230 233 227 222 218 215 202 186 164 152 129 64
230 233 227 222 218 215 213 199 197 217 259 386
230 233 227 230 227 225 236 252 295 347 453 773
230 230 233 233 227 227 230 230 236 236 245 254 269 281 292 319 345 361 412 434 582 614 1031 1095
Zonal Lumen Summary Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 33 54 97 143 1412 2272 3705 4489 4632
0.6 0.9 1.7 2.5 24.3 39.2 63.9 77.4 79.9
0.7 1.2 2.1 3.1 30.5 49.1 80.0 96.9 100.0
RCR
Luminaire
Angle
Luminaire Data Test 11606
RC RW 1 2 3 4 5 6 7 8 9 10
70 70 63 58 53 48 44 40 37 35 32
80 50 30 66 63 58 53 51 45 45 39 40 34 35 29 31 26 28 23 26 20 23 18
10 61 50 41 34 29 25 21 19 16 14
70 60 54 49 45 41 38 35 32 30 27
70 50 30 57 55 50 46 44 39 39 34 34 29 30 25 27 22 24 20 22 17 20 16
10 53 43 36 30 26 22 19 16 14 13
50 40 35 30 27 24 21 19 17 16 14
50 30 38 32 28 24 21 18 16 14 12 11
10 37 31 25 22 18 16 14 12 10 9
Indoor Candela Plot 0 0 2 2 1 1 1 1 1 1 1 1
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
180
165
150
135
1400
120 700 105
90
75 700 60
Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
79.9% 68 Yes-VDT Intensive Use $3.53 based on 3000 hrs. and $0.08 per KWH
1400 0
0.0
15
30 Horiz 0-180
45.0
Page 2/3 Rev. 09/29/09 © 2009 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1580 / Website www.aleralighting.com
45
90.0
Test Date 11/19/96 Curves / AVL CM
Avalon Cable Mount 2, 3, 4-Lamp T8, Direct/Indirect Distribution Photometric Data
Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet
AVL2T8UD-PHRWEB8-4 Avalon Architectural Curve 10" × 49" 2-LAMP WITH PINHOLE ROUND LENS, WHITE SCREEN B232I120RH 0.88 F32T8 2900 60 Pendant 0º = 90 90º = 90 0º = 1.28 90º = 1.28 Length: 4.08 Width: 0.47 Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
174 175 169 167 157 166 146 133 131 108 97 0
174 175 169 167 166 157 157 146 148 152 194 258
174 175 169 167 166 166 168 186 213 260 323 580
174 175 169 175 175 176 202 226 263 304 420 773
174 175 169 175 175 186 202 239 263 325 453 837
Zonal Lumen Summary Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 24 40 72 106 1411 2272 3704 4488 4594
0.4 0.7 1.2 1.8 24.3 39.2 63.9 77.4 79.2
0.5 0.9 1.6 2.3 30.7 49.4 80.6 97.7 100.0
RCR
Luminaire
Angle
Luminaire Data Test 11607
RC RW 1 2 3 4 5 6 7 8 9 10
70 69 63 57 52 48 44 40 37 34 32
80 50 30 66 63 57 53 50 45 44 39 39 33 35 29 31 25 28 22 25 20 23 18
10 60 49 41 34 29 25 21 18 16 14
70 59 54 49 44 41 37 34 32 29 27
70 50 30 56 54 49 46 43 39 38 33 34 29 30 25 27 22 24 19 22 17 20 15
10 52 43 35 30 25 22 19 16 14 12
50 39 34 30 27 24 21 19 17 15 14
50 30 38 32 27 24 20 18 16 14 12 11
10 36 30 25 21 18 15 13 12 10 9
Indoor Candela Plot 0 0 1 1 1 1 1 1 1 0 0 0
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
180
165
150
135
1400
120 700 105
90
75 700 60
Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
79.2% 67 Yes-VDT Intensive Use $3.58 based on 3000 hrs. and $0.08 per KWH
1400 0 0.0
15
30 Horiz 0-180
45.0
45 90.0
Test Date 11/19/96
Photometric Data
Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet
AVL2T8UD-PHRBEB8-4 Avalon Architectural Curve 10" X 49" 2-LAMP WITH PINHOLE ROUND LENS, BLACK SCREEN B232I120RH 0.88 F32T8 2900 60 Pendant 0º = 90 90º = 90 0º = 1.27 90º = 1.37 Length: 4.08 Width: 0.47 Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0 51 52 51 48 44 39 45 40 33 22 32 0
51 52 51 48 44 39 45 40 49 43 32 64
51 52 44 48 52 49 45 53 66 65 97 129
51 52 51 56 52 59 67 66 82 87 129 193
51 52 51 56 52 59 67 66 66 108 129 258
Zonal Lumen Summary Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 7 12 21 31 1410 2270 3703 4487 4518
0.1 0.2 0.4 0.5 24.3 39.1 63.8 77.4 77.9
0.2 0.3 0.5 0.7 31.2 50.3 82.0 99.3 100.0
RCR
Luminaire
Angle
Luminaire Data Test 11608
RC RW 1 2 3 4 5 6 7 8 9 10
70 68 61 56 51 47 43 39 36 34 31
80 50 30 64 62 56 52 49 44 43 38 38 33 34 28 31 25 27 22 25 19 22 17
10 59 48 40 34 28 24 21 18 16 14
70 58 52 48 43 40 36 33 31 29 27
70 50 30 55 53 48 45 42 38 37 33 33 28 29 25 26 22 24 19 21 17 19 15
10 51 42 35 29 25 21 18 16 14 12
50 38 33 29 26 23 20 18 16 15 14
50 30 37 31 27 23 20 17 15 13 12 11
10 35 29 24 21 18 15 13 11 10 9
Indoor Candela Plot 0 0 0 0 0 0 0 0 0 0 0 0
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
180
165
150
135
1400
120 700 105
90
75 700 60
Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
77.9% 66 Yes-VDT Intensive Use $3.64 based on 3000 hrs. and $0.08 per KWH
1400 0
0.0
15
30 Horiz 0-180
45.0
Page 3/3 Rev. 09/29/09 © 2009 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1580 / Website www.aleralighting.com
45
90.0
Test Date 11/19/96