bionisis oplc

saccharose galactose glucose fructose xylose. Plant extract A. Standards. Plant extract B. Plant extract C. Sugar separation. Sorbent : HTSorb™ 11 µm silica.
852KB taille 237 téléchargements 625 vues
3 VOLETS BIONISIS Angl

3/03/00 17:58

Page 3

BIONISIS OPLC

The key to higher

throughput

Ref 9001-3/00 - Printed in France, Specifications subject to change without notice.

in the world of liquid chromatography

BIONISIS

OPLC

3 VOLETS BIONISIS Angl

3/03/00 17:58

Page 1

BIONISIS OPLC Optimum Performance Laminar Chromatography Bionisis is committed to bringing a new concept in liquid chromatography to industrial and academic laboratories. We recognize the need for high throughput, high resolution and low cost. We are dedicated to providing you with solutions and supporting your efforts in implementing OPLC, a major advance

Bionisis OPLC 50 system

in liquid chromatography.

A Bionisis OPLC system in your laboratory means increased productivity through…

 Simultaneous multi-sample processing  Fast separation ( av. 10 to 20 min )  Reduced sample preparation  Low solvent consumption ( < 5ml/run )

The real key to higher throughput OPLC … Optimum Performance Laminar Chromatography

3 VOLETS BIONISIS Angl

3/03/00 17:58

Page 4

OPLC 50 A sturdy, robust system reliable and easy to service Cassette with HTSorb™ chromatographic sorbent

User-friendly programming • Programs run with a limited number of parameters • System set-up in a minute

• Choice of chromatographic techniques (reverse phase, normal phase …) • Selection of particle sizes according to resolution required • No clogging (even with dirty samples), no phantom peaks

Easy solvent change • Flexible solvent composition programming

Low solvent consumption • Only 5 ml of solvent for a complete run involving up to 70 samples at a time

Process up to 70 samples simultaneously OPLC … Optimum Performance Laminar Chromatography

3 VOLETS BIONISIS Angl

3/03/00 17:58

Page 5

BIONISIS OPLC An efficient, robust technique OPLC is a fast and reliable liquid chromatography technique, ideal for laboratories faced with the problem

Separations on 5 µm particles for reproducible separations

of processing a large number of complex mixtures of chemical and biochemical compounds. In OPLC,

the sorbent flat bed is completely covered by a

flexible Teflon® membrane and maintained under pressure in a vapor-free state. The eluent is pushed across the flat sorbent bed at a controlled flowrate. Bionisis OPLC separations are carried out on HTSorb™ «flat» columns. Since the chromatographic support is supplied in ultra-thin (200µm) layers, it is possible to use 3 µm particles with

Two dimensional separations for complex compounds

very limited build-up of back pressure. OPLC provides a wide choice of established detection methods (UV, visible, fluorescence…) plus selective visualisation of compounds. The linear migration of the solvent front makes OPLC an extremely efficient technique. With an HTSorb 5 µm sorbent bed, typical separation time is from 5 to 30 minutes. Analytical or preparative mode with on-line fraction collection

The ultimate in simplicity

1 2 3

Automatically deposit sample on the HTSorb column Load the column into the separation unit Start the program

Separations in 15 minutes ! OPLC … Optimum Performance Laminar Chromatography

3 VOLETS BIONISIS Angl

3/03/00 17:59

Page 6

PHARMACEUTICAL FOOD

The perfect complement to HPLC in your laboratory

AND BEVERAGE

COSMETICS ENVIRONMENTAL

HTSorb™ silica 11 µm Development time : 18 min

CLINICAL

280 nm

RESEARCH

urine 5 urine 4 0.01 µg risperidone 0.1 µg risperidone 1 µg risperidone

AU

0.01 µg clozapine

200 180 160 140 120 100 80 60 40 20 0

0.1 µg clozapine 1 µg clozapine

Sorbent : HTSorb™ HP 5 µm silica Development time (with overrun) : 17 min Sample : 50 µg main component spiked with 0.5 µg of each known impurity (no. 1-4),band size : 10 mm Detection : absorbance at 233 nm

233 nm

urine 3 blank urine 2

AU

urine 1

20

30

40

50

60

70

80

90

100 110 120 130 140 150mm

Psychotropic drugs in urine

100

Personal communication, E.N. Papp and E. Nagy

Sorbent : HTSorb™ HP 5 µm silica Development time (with prewash) : 19.3 min Sample : wheat extract (spiked with 5-5 ng/g B1 B2, G1, G2) Fluorescent detection

0 0

50

100

150

mm

Impurity test (main component : phthaloyl-amlodipine) Prepared in Gedeon Richter Co. Ltd. Z. Végh and K. Ferenczi-Fodor

4

50

xylose

galactose glucose fructose

raffinose

1 2

0

maltose saccharose

Sorbent : HTSorb™ 11 µm silica

3

mm Standards

Aflatoxins in wheat Personal communication,E. Papp and K.H. –Otta Plant extract A

Plant extract B

Plant extract C 0

50

100

150

mm

Sugar separation Personal communication, E. Sárdi

OPLC … Optimum Performance Laminar Chromatography

3 VOLETS BIONISIS Angl

3/03/00 17:58

Page 2

BIONISIS OPLC

Specifications Separation chamber

Dimensions : 39 (L) x 29.6 (W) x 13.5 cm (H) - Weight : 19 kg External pressure : 5 MPa max

Delivery system

Dimensions : 40 (L) x 20.6 (W) x 20 (H) cm - Weight : 11 kg Power input rate : 130 VA Power requirements : 110/220 V, 50HZ Hydraulic liquid supply ; max external pressure : 92 ml/min., 5 MPa Eluent flow range, max eluent pressure : 10-10 000 µl/min., 4.5 MPa Reproducibility of eluent delivery : 0.1%

Sorbent layers for HTSorb™ flat columns Ready-to-use, pre-sealed 200 x 200 x 0.2 mm or 200 x 100 x 0.2 mm aluminum foils HTSorb™ HP HTSorb™ RP 18 HTSorb™

silica, 5 µm particle size silica, 11 µm particle size reverse phase silica, 11 µm particle size

Distributed by

BIONISIS

OPLC

Parc Technologique du Plessis Robinson, Bâtiment "Le Carnot", 18, avenue Edouard Herriot, 92350 Le Plessis Robinson, France Tel 33 (0)1 40 83 82 00 • Fax 33 (0)1 40 83 82 01 • www.bionisis.com • [email protected]

Ref 9001-3/00 - Printed in France, Specifications subject to change without notice.

Optimum Performance Laminar Chromatography OPLC and HTSorb are trademarks of Bionisis, S.A., France. Teflon is a registered trademark of Dupont de Nemours