CETest-UserManual-1 - Index of

Dec 18, 2006 - Binary representation of sensor flags ... Intensity for printing pressure 50-150 (0 = last value). ... Print text below barcode with encoded data.
338KB taille 32 téléchargements 429 vues
CE-Test User- and Installation Manual

Author: SCCP Version: 1.3 18.12.2006

UserManual CE-Test

SKIDATA AG Untersbergstraße 40 A-5083 Grödig/Salzburg Phone: +43 (0) 62 46/8 88-0 Fax: +43 (0) 62 46/8 88-7 Internet: http://www.skidata.com/ e-mail: [email protected] Copyright © 2006 by SKIDATA AG. All rights reserved. All information in the following document is protected by copyright law. No part of this document may be reproduced without the written consent of SKIDATA AG. SKIDATA AG reserves the right to make any changes of specification and other information in this document without further notice. Please Note During the compilation of this Technical Documentation , great care has been taken to ensure the accuracy of the information contained in it. However, despite our constant effort to ensure the highest degree of accuracy and comprehensiveness possible, the information provided cannot be guaranteed to be absolutely error-free. Trademarks This documentation may contain representations of registered product or service trademarks owned by SKIDATA AG or third parties, as well as references to proprietary know-how protected by copyright laws or other legal provisions. In any case the intellectual property rights remain exclusively with their respective owners. Notice This documentation is released for SKIDATA service technicians and partners authorised by SKIDATA headquarter.

Version History Date

Version

Changed by

Description of Changes

24.5.06

1.0

SCCP

Initial version

29.8.06

1.1

PFMA

Extension System Requirements

8.11.06

1.2

PFMA

Extension of tabfolder Code-Draw

18.12.06

1.3

SCCP

Installation Guide added

© 2006 SKIDATA AG

Table of Contents

Page 2 of 2

UserManual CE-Test 1.

Table of Contents

2. 2.1 2.2 2.3

UserManual CETest.......................................................................................................4 System Requirements.................................................................................................4 Installation ...................................................................................................................4 User Interface..............................................................................................................5

2.3.1 2.3.1.1 2.3.1.2

2.3.2 2.3.2.1 2.3.2.2 2.3.2.3 2.3.2.4 2.3.2.5 2.3.2.6 2.3.2.7 2.3.2.8 2.3.2.9 2.3.2.10 2.3.2.11

Monitor / Trace window: ............................................................................... 6 Global settings........................................................................................................7 Connection Status ..................................................................................................7

Command window........................................................................................ 8 General tabfolder....................................................................................................8 Code-Draw tabfolder ..............................................................................................9 Code-Text tabfolder..............................................................................................10 Code-Barcode tabfolder .......................................................................................11 Code-Magnet tabfolder.........................................................................................12 Code-Bitmap tabfolder..........................................................................................13 Code-Bon tabfolder ..............................................................................................14 Read tabfolder ......................................................................................................15 Transport tabfolder ...............................................................................................16 Settings tabfolder .................................................................................................17 Download tabfolder ..............................................................................................18

© 2006 SKIDATA AG

Table of Contents

Page 3 of 3

UserManual CE-Test 2.

UserManual CETest

This manual describes the usage of SKIDATA CE-Test V1.75 and higher. Use CE-Test to verify the functionality of any type of Coder Unlimited (CarAccess and PeopleAccess).

2.1

System Requirements

CE-Test V1.75 requires installed Microsoft .NET 1.1 (or higher) and SKIDATA Communication Layer 2.20 for Microsoft .NET. A USB-driver for Coder Unlimited is included in the installation files. CE-Test can be downloaded from SKIDATA TechRepository and is included in SKIDATA CarAccess Tools CD. Coder Unlimited can be connected by using a serial or USB connection.

2.2

Installation

Enter the Directory, were CETest is located and run Setup.exe. The Wizard will guide you through the installation, which is a standard Windows installation package. After the installation process a program folder is created, which looks like the picture below.

Structure of the start up menu

If you install CETest the first time, start Setup Commlayer before running CETest, because starting it directly may cause an exception. Running Setup Commlayer installs the Communication Layer to your system and configures it for running with the Coder Unlimited. The Installation is done with a standard Windows installation. After this step you can start CETest from the Start Menu. Anytime you experience problems with CETest, try running Setup Commlayer.

© 2006 SKIDATA AG

UserManual CETest

Page 4 of 4

UserManual CE-Test

2.3

User Interface

Monitor- / Trace window

Connection information

Command window

© 2006 SKIDATA AG

UserManual CETest

Global settings

Page 5 of 5

UserManual CE-Test

Tracewindow

2.3.1 Monitor / Trace window: In comparison to the Trace window, only received data is displayed in the Monitor window and data is decoded to a readable layout in most cases. Data is displayed in hex and character in one trace window. Sent data is displayed in the same window, time will be logged in the tracefile.

© 2006 SKIDATA AG

UserManual CETest

Page 6 of 6

UserManual CE-Test

2.3.1.1 Global settings Source Source position for ticket transport Also used for coding- and reader-operation Destination Destination position for ticket transport Also used for coding- and reader-operation Leporello Cutting-options (including delayed transport) Also used for coding- and reader-operation Sensor Flags Binary representation of sensor flags (see tabfolder Read) Pressure Contact pressure 1-4 (0 = last value) Levels equal a contact pressure of 10N ,20N ,30N und 40N Intensity Intensity for printing pressure 50-150 (0 = last value). This value is a level for heating time in %. Intensity is adjusted automatically with lengthwise orientation. Erase Intensity for erasing ticket 50-150 (0 = last value) See intensity 2.3.1.2 Connection Status

Connection Status Status of connection green = connected red = disconnected grey = no device found

Serial numbers All detected devices are listed with serial numbers. Select a device to mark it, a connection will be initiated. If only one device is listed, a connection will be initiated automatically. Refresh devices Refresh of listed/connected devices

© 2006 SKIDATA AG

UserManual CETest

Page 7 of 7

UserManual CE-Test

Drop Down Menü The connection type can be selected in this menu. All available media types are listed, most commands are available with USB only.

2.3.2 Command window 2.3.2.1 General tabfolder

Get LB values Reads values for lightbarriers analog and digital. Decoded values are displayed in the monitor window. Get Ticket Positions Reads used ticket positions. These positions are the logical saved positions in the firmware and therefor independent from the lightbarriers. Selftest Displays the difference from Current state to Target state of components Get ADC Status Displays analog values as heating threshold values or currencies Is Alive An Acknowledge is sent by Coding Unit if it is operating properly Set Equipment Initiates a scan of current state of components and saves this state as new target state Get Equipment Displays current state of components Add. Equip. Info Displays additional information of components for BLL and barcode scanner

© 2006 SKIDATA AG

UserManual CETest

Page 8 of 8

UserManual CE-Test Get ID Displays IDs of components Get version Displays Firmware/FPGA Version

2.3.2.2 Code-Draw tabfolder

General part of window Start Download Initiates a download with selected parameters. Set parameters can be read by using ‚?’ Download Data Initiates a download into Coding Unit. Several downloads of data are possible after selecting „Start Download“ Code Ticket Coding of ticket by using selected parameters 1+2+3 A combination of Start Download, Download Data und Code Ticket will be initiated automatically. Error Handling Type of error handling when re-reading ticket. Activate this option for automatic adjustment of intensity when printing lengthwise barcode. Erase Erase of TRW-tickets (1+2+3 must be executed). To erase a TRW-ticket a testpattern has to be selected. Metamorphose Erase and imprint of a TRW-ticket in one step Slow Print Mode Imprinting of tickets with half speed (lengthwise barcode)

© 2006 SKIDATA AG

UserManual CETest

Page 9 of 9

UserManual CE-Test Keep Printbuffer Selected data will be saved and used for next ticket production

Specific part of window Frame Imprinting of frame at the selected position Line Imprinting of a line at the selected position Circle Imprinting o a circle at the selected position Testpattern Imprinting of a test ticket with selected test pattern 2.3.2.3 Code-Text tabfolder

X-Position x-position of printed text Y-Position y-position of printed text Font Index of imprinted font 0-15 Rotation Orientation of text Text Printed text Underline Text underlined Bold Bold text Width x 2 Print text with double width

© 2006 SKIDATA AG

UserManual CETest

Page 10 of 10

UserManual CE-Test Height x 2 Print text with double height 2.3.2.4 Code-Barcode tabfolder

Barcode Type 40 Lengthwise barcode 450 Barcode Type 42 Crosswise barcode SPT400 Barcode Type 43 (EAN) EAN barcode (price labels etc.) This barcode type can not be read by Coder Unlimited. BC with Text Print text below barcode with encoded data BC with Border Print frame around barcode x-Position x-position of imprinted barcode (only type 42 und 43) y-Position y-position of imprinted barcode Rotation Orientation of barcode BC Module Thickness of one bar of the barcode Height Height of imprinted barcode Get BC Length Responds with the length of entered data Data Encoded data

© 2006 SKIDATA AG

UserManual CETest

Page 11 of 11

UserManual CE-Test

2.3.2.5 Code-Magnet tabfolder

SKIDATA 450 Skidata 450 Magnetic stripe ticket SKIDATA 440 SKIDATA 440 Magnetic stripe ticket (2 magnetic stripes) Erase Ticket Erase ticket magnetically Track1 Data of track 1 Track2 Data of track 2 Track3 Data of track 3 Density Bit-density of track (only for information, no effect on encoding)

© 2006 SKIDATA AG

UserManual CETest

Page 12 of 12

UserManual CE-Test

2.3.2.6 Code-Bitmap tabfolder

x-position x-position of printed bitmap y-position y-position of printed bitmap Bitmapfile Filename of bitmap, black and white, max. 639 x 1023 pixels (portrait format) Double Height Print bitmap with double height Double Width Print bitmap with double width Another Bitmap on same Y Coordinate Print a second bitmap on same y-position

© 2006 SKIDATA AG

UserManual CETest

Page 13 of 13

UserManual CE-Test

2.3.2.7 Code-Bon tabfolder

Start Bon Download Initiates the download of a bon Start the download of data by using the “Download Data” command Start Bon Printing Initiates printing of a bon Download of bon data is similar to the download of printing data, except y-position is added to the last position, which means that a y-position 0 causes printing in the next line.

© 2006 SKIDATA AG

UserManual CETest

Page 14 of 14

UserManual CE-Test

2.3.2.8 Read tabfolder

Sensorflags Selection of used sensors. This selection effects the display on right side of the window. Chip Down Brings down the chip contact Chip Up Lifts the chip contact Activate Reading Activates reading from source position with selected sensorflags. The coding unit will wait for a ticket in source position. Deactivate Reading De-activation or reading Read Ticket Reads a ticket from source position, without any delay. Directory Reads content of a BLL datacarrier without any transport command (BLL direct communication) Read keycard Reads data of a BLL datacarrier without any transport command (BLL direct communication)

© 2006 SKIDATA AG

UserManual CETest

Page 15 of 15

UserManual CE-Test

2.3.2.9 Transport tabfolder

Leporello Cutting options CutPosition Set cutting position of leporello-tickets Transport Initiates a ticket transport from source- to tagetposition Reverse Initiates a ticket transport from target- to sourceposition Empty to Destination Transport loaded ticket from coding unit to target-position Incl Parkpositions Empty parking position when command is sent. From – To Printposition Shortcuts for often used transport commands

© 2006 SKIDATA AG

UserManual CETest

Page 16 of 16

UserManual CE-Test

2.3.2.10

Settings tabfolder

Request Acknowledge All commands will be extended with a request for acknowledge. Auto Connect Connect automatically, if a device is found Read Trace File Displays the content of a tracefile Delete Trace File Delete tracefile Delete Backup Files Delete all backup files Multiple Backup Create multiple backupfiles Show Empty Read Display reading commands, with no data reply Mode Output mode Time Time 1/10 Time will be entered in 0,1 sec 1/1000 Time will be entered in ms Set Port1 Use settings for Port1 Set Port2 Use settings for Port2 Falling Send message with falling edge on selected input channel Rising Send message with rising edge on selected input channel

© 2006 SKIDATA AG

UserManual CETest

Page 17 of 17

UserManual CE-Test Set Use selected settings for inputs 2.3.2.11 Download tabfolder

SD605 Download Download firmware directly into SD605 USB Download Download firmware for coding unit mechanics over USB

© 2006 SKIDATA AG

UserManual CETest

Page 18 of 18