Chapter 10: Valves for Pipe Mounting
Catalogue HY11-3500/UK
Contents
Description
Size
DIN / ISO
— —
R4V R4R
— —
R4V R4R
—
D4S
MV / 9MV N / 9N F / 9F PCM / 9PCM
— — — —
C / 9C 6C CP / 9CP RH
— — — —
Pressure valves, manual operation Pressure relief function Pressure reducing function Pressure valves, proportional operation Pressure relief function Pressure reducing function Directional seat valves In-line mounted Flow valves Throttle valve, with handle Throttle valve, with knob Throttle valve, with check valve Flow control valve, manual op. Check valves Direct operated Direct operated Pilot operated Pilot operated Accessories Plug-in connectors
Body
Page
1/8 ¼ 3/8 ½ ¾ 1 1¼ 1½ 2 M16 x 1.5 M18 x 1.5 M22 x 1.5 M27 x 2 L-port T-port
Series Denison Parker
• • • • • • • •
• •
• •
10-3 10-9
• • • • • • • •
• •
• •
10-15 10-21
• • • •
•
•
10-27
• • • • • • • • • • • • • • •
• • • •
• • • • • • •
• • • • • • • • • • • •
10-37 10-39 10-41 10-43
• • • •
10-45 10-47 10-49 10-51 10-55
10
content10.INDD RH
10-1
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Notes
10
content10.INDD RH
10-2
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Pressure Relief Valve Series R4V (Denison)
Catalogue HY11-3500/UK
Characteristics Pilot operated pressure relief valves for in-line mounting series R4V have a similar design to the subplate mounted R4V series. For single functions - where no manifold blocks are used - the valves can be directly placed in the pipework. The R4V valves are available with 2 ports (L-body) for in-line relief function or with 3 ports (T-body) for relief functions in the bypass. Features • Pilot operated with manual adjustment • 2 interfaces - L-body (R4V06-G¾", R4V10-G1¼") - T-body (R4V03-G½", R4V06-G1") • 3 pressure stages • 3 adjustment modes - Hand knob - Acorn nut with lead seal - DIN lock • With optional vent function
R4V10 L-body
R4V06 L-body
10
R4V_UK.INDD RH
10-3
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Pressure Relief Valve Series R4V (Denison)
Catalogue HY11-3500/UK
Ordering Code Ordering code
R4V Pressure relief valve
5 Nominal size
Code
Nominal size
03
NG10 (G½")
06
NG25 (G1" - T-body, G¾" - L-body)
10
NG32 (G1¼")
Code
Body R4V03 T-body R4V06 T-body R4V06 L-body R4V10 L-body
6 D
Max. pressure 350 bar
A Body
Pressure stages
Adjustment
Drain line
Switching Solenoid type voltage
Design series
Seal
Code 1 5
Options
Seal NBR FPM
Code Solenoid voltage w/o omit Standard vent function G0R 12V= G0Q 24V= GAR 98V= GAG 205V= W06 115V / 50Hz W07 230V / 50Hz Code Switching type Standard w/o vent function Solenoid not activ. 09 1) unpress. circulation Solenoid activated 11 2) unpress. circulation 1) Sol. de-energized: open to tank Sol. energized: vent line blocked 2) Sol. de-energized: vent line blocked Sol. energized: open to tank omit
Code Pressure stages 1 up to 105bar 3 up to 210bar 5 up to 350bar
Code 1 3 4
Adjustment Hand knob Acorn nut with lead seal DIN lock
Code 0
10
2
Drain line internal external from pilot head (Y1)
R4V_UK.INDD RH
10-4
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Pressure Relief Valve Series R4V (Denison)
Catalogue HY11-3500/UK
Technical Data R4V General Size Mounting Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration
L-body
T-body 03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 3.2
06 (1")
06 (¾")
10 (1¼")
6.6
3.3
5.6
[bar] Ports A and X up to 350; Ports B and Y 30 bar [bar] 105, 210, 350 60 200 200 [l/min] Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 10...650 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
450
R4V with vent function General Size Mounting Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Electrical (solenoid) Duty ratio Response time
T-body 03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 4.9
L-body 06 (1")
06 (¾")
10 (1¼")
8.3
5.0
7.3
[bar] Ports A and X up to 350; Ports B and Y 30 [bar] 105, 210, 350 [l/min] 60 200 200 Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 10...650 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
450
[%] 100 [ms] Energized / de-energized AC: 20/18 , DC: 46/27
Supply voltage Tolerance supply voltage Power consumption hold in rush Max. switching frequency Solenoid connection Protection class Coil insulation class
Code
G0R 12V = +5...-10 31 31
G0Q 24V = +5...-10 31 31
GAR 98V = +5...-10 31 31
GAG 205V = +5...-10 31 31
W06 W07 150 at 50Hz 230 at 50Hz +5...-10 +5...-10 78 78 264 264
AC: up to7.200, DC: up to 16.000 switchings/hour Connector as per EN175301-803 IP65 in accordance with EN 60529 (plugged and mounted) H (180 °C)
R4V_UK.INDD RH
10-5
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
10
Characteristic Curves / Dimensions
Pilot Operated Pressure Relief Valve Series R4V (Denison)
p/Q performance curve Series R4V 1)
Minimum pressure curve
Catalogue HY11-3500/UK
1) The performance curves are measured with external drain. For internal drain the tank pressure has to be added to curve.
Dimensions R4V*06 T-body
10
R4V_UK.INDD RH
10-6
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Pressure Relief Valve Series R4V (Denison)
Catalogue HY11-3500/UK
Dimensions Dimensions R4V*06 L-body
10 NG 03 06 06 10
1) 2)
Body T-body T-body L-body L-body
B1 85 136 -
B2 81 120.7
B3 76 85.8
B4 43 77.8
Ports
Function
A B X1) Y12)
pressure (inlet) tank (outlet) ext. remote control or vent connection external drain
H1 27.5 38 -
H2 21 28 -
H3 59.5 93 -
R4V03 T-body G½ " G½ "
H4 97.5 131 -
H5 23 31.8
H6 51 50.8
H7 81 96
H8 119 134
Port size R4V06 L-body R4V06 T-body G¾ " G1 " G¾ " G1 "
L1 53 66.5 -
L2 92 117.5 -
L3 49 49.8
R4V10 L-body G1¼ " G1¼ "
G¼ "
closed when supplied port Y1 is only available at drain line (code2) external from the pilot head
R4V_UK.INDD RH
10-7
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Pressure Relief Valve Series R4V (Denison)
Catalogue HY11-3500/UK
Dimensions Dimensions R4V with vent function
Code
Internal drain
External drain
10 11
09
R4V_UK.INDD RH
10-8
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Pressure Reducing Valve Series R4R (Denison)
Catalogue HY11-3500/UK
Characteristics Pilot operated pressure reducing valves for in-line mounting series R4R have a similar design to the subplate mounted R4R series. For single functions - where no manifold blocks are used - the valves can be directly placed in the pipework. The valves are available with 2 ports (L-body) or with 3 ports (T-body).
Features • Pilot operated with manual adjustment • Normally closed to avoid undesired motion • 2 interfaces - L-body (R4R06-G¾", R4R10-G1¼") - T-body (R4R03-G½", R4R06-G1") • 3 pressure stages • 3 adjustment modes - Hand knob - Acorn nut with lead seal - DIN lock • With optional vent function
R4R10 L-body
R4R06 L-body
10
R4R_UK.INDD RH
10-9
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Pressure Reducing Valve Series R4R (Denison)
Catalogue HY11-3500/UK
Ordering Code Ordering code
R4R Pressure redu- Nominal cing valve size
Code
Nominal size
03
NG10 (G½")
06
NG25 (G1" - T-body, G¾" - L-body)
10
NG32 (G1¼")
Code
Body R4R03 T-body R4R06 T-body R4R06 L-body R4R10 L-body
6 D
2
5 Max. pressure 350 bar
Body
Pressure stages
Adjustment
B
Drain Switching Solenoid type voltage line ext. from pilot head (Y1)
3 4
Seal
Code 1 5
Options
Seal NBR FPM
Code Solenoid voltage w/o omit Standard vent function G0R 12V= G0Q 24V= GAR 98V= GAG 205V= W06 115V / 50Hz W07 230V / 50Hz
Code Pressure stages 1 up to 105bar 3 up to 210bar 5 up to 350bar
Code 1
Design series
Code Switching type Standard w/o vent function 1) Solenoid not activ. 09 unpress. circulation Solenoid activated 11 2) unpress. circulation 1) Sol. de-energized: open to tank Sol. energized: vent line blocked 2) Sol. de-energized: vent line blocked Sol. energized: open to tank omit
Adjustment Hand knob Acorn nut with lead seal DIN lock
10
R4R_UK.INDD RH
10-10
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Pressure Reducing Valve Series R4R (Denison)
Catalogue HY11-3500/UK
Technical Data R4R General Size Mounting Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration
T-body 03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 3.2
L-body 06 (1")
06 (¾")
10 (1¼")
3.3
5.6
6.6
[bar] Ports A, B and X: 350; Port Y depressurized [bar] 105, 210, 350 [l/min] 90 300 300 Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 10...650 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
600
R4R with vent function General Size Mounting Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Electrical (solenoid) Duty ratio Response time
03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 4.9
06 (¾")
06 (1")
10 (1¼")
5.0
7.3
8.3
[bar] Ports A and X up to 350; Ports B and Y depressurized [bar] 105, 210, 350 60 200 200 [l/min] Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 10...650 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
450
[%] 100 [ms] Energized / de-energized AC: 20/18 , DC: 46/27
Supply voltage Tolerance supply voltage Power consumption hold in rush Max. switching frequency Solenoid connection Protection class Coil insulation class
Code
G0R 12V = +5...-10 31 31
G0Q 24V = +5...-10 31 31
GAR 98V = +5...-10 31 31
GAG 205V = +5...-10 31 31
W06 W07 150 at 50Hz 230 at 50Hz +5...-10 +5...-10 78 78 264 264
AC: up to7.200, DC: up to 16.000 switchings/hour Connector as per EN175301-803 IP65 in accordance with EN 60529 (plugged and mounted) H (180 °C)
R4R_UK.INDD RH
10-11
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
10
Catalogue HY11-3500/UK
Characteristic Curves
Pilot Operated Pressure Reducing Valve Series R4R (Denison)
Reduced pressure pA versus flow Q Series R4R03 1)
Minimum pressure curve
Reduced pressure pA versus flow Q Series R4R06 1)
Minimum pressure curve
Reduced pressure pA versus flow Q Series PR32M 1)
Minimum pressure curve
10
1)
Measured at 350 bar primary pressure pB.
R4R_UK.INDD RH
10-12
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Dimensions
Pilot Operated Pressure Reducing Valve Series R4R (Denison)
T-body
L-body
Catalogue HY11-3500/UK
NG 03 06 06 10
Body T-body T-body L-body L-body
B1 85 136 -
B2 81 120.7
B3 76 85.8
Ports
Function
B A X1 Y1
pressure (inlet) pressure (outlet) ext. remote control or vent connection external drain
B4 43 77.8
H1 27.5 38 -
H2 59.5 93 -
R4V03 T-body G½ " G½ "
H3 97.5 131 -
H4 51 50.8
H5 81 96
H6 119 134
L1 53 66.5 -
Port size R4V06 L-body R4V06 T-body G¾ " G1 " G¾ " G1 "
L2 92 117.5 -
L3 49 49.8
R4V10 L-body G1¼ " G1¼ "
G¼ "
R4R_UK.INDD RH
10-13
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
10
Pilot Operated Pressure Reducing Valve Series R4R (Denison)
Catalogue HY11-3500/UK
Dimensions Dimensions R4R with vent function
Code
External drain
11
09
10
R4R_UK.INDD RH
10-14
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Characteristics Proportional pressure relief valves series R4V*P2 are based on the mechanically adjusted series R4V. The additional proportional unit between the mechanical pilot valve and the main stage allows continuous pressure adjustment. The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400.
Features • Pilot operated with manual adjustment • Continuous adjustment by proportional solenoid • 2 interfaces - L-body (R4V06-G¾", R4V10-G1¼") - T-body (R4V03-G½", R4V06-G1") • 3 pressure stages • With mechanical maximum pressure adjustment
R4V10*P2 L-body
R4V06*P2 L-body
10
R4VP2_UK.INDD RH
10-15
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Ordering Code / Technical Data Ordering code
R4V Proportional pressure relief valve
Size
Code
Nominal size
03
NG10 (G½")
06
NG25 (G1" - T-body, G¾" - L-body)
10
NG32 (G1¼")
Code
Body R4V03 T-body R4V06 T-body R4V06 L-body R4V10 L-body
6 D
P2
5 Max. pressure 350 bar
Body
Pressure stages
Adjustment
Drain line
G0R
Proportional Solenoid pressure voltage control 12V=
A Design series
Seal
Code 1 5
Seal NBR FPM
Code 0
Drain line internal external from pilot head (Y1)
2
Code 1 3
Code Pressure stages 1 up to 105bar 3 up to 210bar 5 up to 350bar
Options
Adjustment Hand knob Acorn nut with lead seal
Technical data R4V*P2
10
General Size Mounting Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Electrical (prop. solenoid) Duty ratio Nominal voltage Max. current Coil resistance Protection class Power amplifier
L-body
T-body 03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 5.0
06 (1")
06 (¾")
10 (1¼")
5.1
7.4
8.4
[bar] Ports A and X up to 350; Ports B and Y 30 bar [bar] 105, 210, 350 90 300 300 [l/min] Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 20...380 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7) [%] [V] [A] [Ohm]
600
100 12= 2.3 4 at 20°C IP65 in accordance with EN 60529 (plugged and mounted) PCD00A-400
R4VP2_UK.INDD RH
10-16
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Characteristic Curves Signal/pressure curve R4V
p/Q performance curves 1) R4V03
R4V06
R4V10
Minimum pressure curve RE*M*W 1) R4V03 R4V06
R4V10
1)
10
The performance curves are measured with external drain. For internal drain the tank pressure has to be added to curve.
R4VP2_UK.INDD RH
10-17
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Dimensions T-body
10
NG 03 06
Body T-body T-body
Ports
B1 85 136 Function
H1 27.5 38
H2 21 28
H3 59.5 93
H4 144.5 178
H5 106.5 140
L1 53 66.5
L2 92 117.5
Port size R4V03*P2 T-body G½ " G½ "
A pressure (inlet) B tank (outlet) X1) ext. remote control or vent connection Y12) external drain 1) closed when supplied 2) port Y1 is only available at drain line (code2) external from the pilot head
R4V06*P2 T-body G1 " G1 " G¼ "
R4VP2_UK.INDD RH
10-18
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Dimensions L-body
10
NG 06 10 Ports
Body L-body L-body
B2 81 120.7 Function
B3 76 85.8
H6 23 31.8
H7 51 50.8
H8 81 96
H9 166 181
H10 128 143
L3 49 49.8
Port size R4V06 L-body G¾ " G¾ "
A pressure (inlet) B tank (outlet) X1) ext. remote control or vent connection Y12) external drain 1) closed when supplied 2) port Y1 is only available at drain line (code2) external from the pilot head
R4V10 L-body G1¼ " G1¼ " G¼ "
R4VP2_UK.INDD RH
10-19
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Notes
10
R4VP2_UK.INDD RH
10-20
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Prop. Pressure Reducing Valve Series R4R*P2 (Denison)
Catalogue HY11-3500/UK
Characteristics / Ordering Code Proportional pressure reducing valves series R4R*P2 are based on the mechanically adjusted series R4R. The additional proportional unit between the mechanical pilot valve and the main stage allows continuous pressure adjustment. The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400.
Features • Pilot operated with proportional solenoid • Normally closed to avoid undesired motion • Continuous adjustment by proportional solenoid • 2 interfaces - L-body (R4R06-G¾", R4R10-G1¼") - T-body (R4R03-G½", R4R06-G1") • 3 pressure stages • With mechanical maximum pressure adjustment
R4R10*P2 L-body
R4R06*P2 L-body
Ordering code
R4R Pressure reducing valve
5 Nominal size
Code
Nominal size
03
NG10 (G½")
06
NG25 (G1" - T-body, G¾" - L-body)
10
NG32 (G1¼")
Max. pressure 350 bar
2 Body
Pressure stages
Adjustment
P2
G0R
Drain Proportional Solenoid pressure voltage line ext. control 12V= from pilot head (Y1)
B Design series
Seal
Code 1 5
Seal NBR FPM
Code 1
Adjustment Hand knob Acorn nut with lead seal
3 Code 6 D
Body R4R03 T-body R4R06 T-body R4R06 L-body R4R10 L-body
Options
Code Pressure stages 1 up to 105bar 3 up to 210bar 5 up to 350bar
R4RP2_UK.INDD RH
10-21
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
10
Catalogue HY11-3500/UK
Technical Data / Characteristic Curves
Pilot Operated Prop. Pressure Reducing Valve Series R4R*P2 (Denison)
Technical data R4R General Size Mounting Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration
T-body 03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 5.0
L-body 06 (1")
06 (¾")
10 (1¼")
5.1
7.4
8.4
[bar] Ports A, B and X up to 350; Port Y depressurized [bar] 105, 210, 350 60 200 200 [l/min] Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 20...380 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Electrical (prop. solenoid) Duty ratio Nominal voltage Max. current Coil resistance Protection class Power amplifier
[%] [V] [A] [Ohm]
450
100 12= 2.3 4 at 20°C IP65 in accordance with EN 60529 (plugged and mounted) PCD00A-400
Command/pressure curve
10
R4RP2_UK.INDD RH
10-22
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Characteristic Curves
Pilot Operated Prop. Pressure Reducing Valve Series R4R*P2 (Denison)
Reduced pressure pA versus flow Q Series R4R03 1)
Minimum pressure curve
Reduced pressure pA versus flow Q Series R4R06 1)
Minimum pressure curve
Reduced pressure pA versus flow Q Series R4R10 1)
Minimum pressure curve
1)
10
Measured at 350 bar primary pressure pB.
R4RP2_UK.INDD RH
10-23
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Prop. Pressure Reducing Valve Series R4R*P2 (Denison)
Catalogue HY11-3500/UK
Dimensions T-body
10
NG 03 06
Body T-body T-body
B1 85 136
Ports
Function
B A X1 Y1
pressure (inlet) pressure (outlet) ext. remote control or vent connection external drain
H1 27.5 38
H2 59.5 93
H3 144.5 178
H4 106.5 140
L1 53 66.5
L2 92 117.5
Port size R4V03*P2 T-body G½ " G½ "
R4V06*P2 T-body G1 " G1 " G¼ "
R4RP2_UK.INDD RH
10-24
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Prop. Pressure Reducing Valve Series R4R*P2 (Denison)
Catalogue HY11-3500/UK
Dimensions L-body
10
NG 06 10
Body L-body L-body
B2 81 120.7
Ports
Function
B A X1 Y1
pressure (inlet) pressure (outlet) ext. remote control or vent connection external drain
B3 76 85.8
H6 51 50.8
H7 81 96
H8 166 181
H9 128 143
L3 49 49.8
Port size R4V06*P2 L-body G¾ " G¾ "
R4V10*P2 L-body G1¼ " G1¼ " G¼ "
R4RP2_UK.INDD RH
10-25
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Notes
10
R4RP2_UK.INDD RH
10-26
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Directional Seat Valve Series D4S (Denison)
Catalogue HY11-3500/UK
Characteristics
Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01) and position control - allow to design individual hydraulic solutions for nominal flow up-to 600 l/min. A complete program is offered under the Denison brand: subplate mounted valves (D4S - chapter 6), SAE flange valves (D5S - chapter 9), pipe mounted valves (D4S - chapter 10), slip-in cartridges (CAR - on request).
D4S10 L-body
Features • Leak-free seat valve design • 2 body designs - L-body (2-port) - T-body (3-port) • Numerous pilot options • 6 poppet types • 4 port sizes - G 1/2“, G1“ for T-body - G 3/4“, G 1 1/4“ for L-body
D4S06 L-body
10
D4S_UK.INDD RH
10-27
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Directional Seat Valve Series D4S (Denison)
Catalogue HY11-3500/UK
Ordering Code
B
D4S Seat valve Code 03 06 10
Code 6 D
Code 1 2 Code 1 C 2 6 3 4
Nominal size
Body
Pilot Cap connection version
Sleeve
Spool type
Spring
Switching Solenoid type voltage
Port size NG10 (CAR4 build-in) NG25 (CAR2 build-in) NG32 (CAR2 build-in)
Code omit 013 Code 1 5
Body Ports D4S03 T-body A, B = G½"; X, Y1 = G¼" D4S06 T-body A, B = G1"; X, Y1 = G¼" D4S06 L-body A, B = G¾"; X, Y1 = G¼" D4S10 L-body A, B = G1¼"; X, Y1 = G¼" Pilot oil line in body A-X B-Y internal from A internal from X
Code omit 09 10 11 12
Ports
X Y Z X-Y Y1 VV01 Standard Pilot oil = pilot drain — — Pilot oil = pilot drain — With solenoid valve (VV01) Ext. PD from cap — Internal pilot drain — — With stroke limiter (not for D4S03) Pilot oil = pilot drain — — — — Pilot oil = pilot drain — — — —
Shuttle valve
DA
Shuttle valve
BH
Size
1
03, 06,10
2 4 A1) B1) C1) 1)
03 06, 10 03, 06,10 06, 10 06, 10 06, 10
BK BN
Poppet type Sleeve With closed bottom and 15° chamfer (pZ max. 1 = pA +20bar With 0.8 dia. orifice at the bottom and 15° 1 chamfer With 1.2 dia. orifice at the bottom and 15° 1 chamfer With closed bottom and 45° chamfer 1, 3 Safety spool (for position control only) 3 Throttle spool, 10° chamfer 3 Throttle spool, 3° chamfer 3
Springs 2, 3, 4 and 6 only
BQ BC BE BA BF BL 2)
Code 1 2 3 4 5 6 7
D4S_UK.INDD RH
Options Standard Cover for position control Seals NBR FPM
VV01 code 09 and shuttle valve code CA VV01 code 11 and shuttle valve code CA VV01 code 09 and shuttle valve code DA VV01 code 11 and shuttle valve code DA VV01 code 10 and shuttle valve code CA and position control 2) with amplifier VV01 code 12 and shuttle valve code CA and position control 2) with amplifier VV01 code 10 and shuttle valve code DA and position control 2) with amplifier VV01 code 12 and shuttle valve code DA and position control 2) with amplifier VV01 code 10 and position control 2) with amplifier VV01 code 12 and position control 2) with amplifier Position control 2) with amplifier Position control 2) with amplifier and shuttle valve code CA Position control 2) with amplifier and shuttle valve code DA
Position control for D4S06/10 only. Spring 2 or 4. Spool A and sleeve 3. Valve open: proximity switch damped
Spring (approx. cracking pressure [bar] Sleeve Code 1 Sleeve Code 3 A -> B A -> B B -> A D5S03 D5S06/10 D5S03 D5S06/10 D5S03 D5S06/10 2.8 3.5 6.5 6.5 9.5 11.0 0.5 0.5 1.0 1.0 1.5 1.7 0.3 0.3 0.6 0.6 0.9 1.0 2.2 2.2 4.0 3.5 5.5 6.0 — 9.0 — 16.0 — 28.0 1.2 1.2 2.0 2.2 3.0 3.8 3.0 — 8.0 — 12.0 —
10-28
Home
Options
Switching type Standard VV01 with manual override de-energized: power comp. open VV01 without manual override VV01 with manual override de-energized: power comp. closed VV01 without manual override
CA
CB CD DB DD
Code Sleeve 1 AA=95%, AB=5% 3 AA=60%, AB=40%
Code
Seals
Code Solenoid voltage omit Standard G0R 12V= G0Q 24V= GAR 98V= GAG 205V= W06 115V / 50Hz W07 230V / 50Hz
open bore closed bore orifice Ø 1.2 Note: Combination examples at the end of chapter
10
Design series
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Technical Data
Directional Seat Valve Series D4S (Denison)
Technical data General Size Mounting Mounting position Ambient temperature Weight
L-body
T-body
D4S T-body D4S L-body
Hydraulic Max. operating pressure Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration
03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 3.2 [kg] —
06 (1")
06 (¾")
10 (1¼")
6.6 —
— 3.3
— 5.6
[bar] Ports A, B up to 350; Port Y 140 (with VV01) [l/min] 180 360 360 Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 10...650 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Electrical (solenoid) Duty ratio Response time Supply voltage Tolerance supply voltage Power consumption, hold Power consumption, in rush
[%] 100 [ms] Energized / de-energized AC: 20/18 , DC: 46/27 Code G0R G0Q GAR GAG [V] 12V = 24V = 98V = 205V = [%] +5...-10 +5...-10 +5...-10 +5...-10 [W] 31 31 31 31 31 31 31 31 [W]
600
W06 W07 150 at 50Hz 230 at 50Hz +5...-10 +5...-10 78 78 264 264
[1/h] AC: up to 7.200, DC: up to 16.000 switchings/hour Connector as per EN175301-803 IP65 in accordance with EN 60529 (plugged and mounted) H (180 °C)
Max. switching frequency Solenoid connection Protection class Coil insulation class
10 D4S pilot configuration L-body (2-port)
T-body (3-port)
D4S_UK.INDD RH
10-29
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Directional Seat Valve Series D4S (Denison)
Catalogue HY11-3500/UK
Characteristic Curves
p/Q performance curves
10
Selection of Cartridges Sleeve 1, poppet 1
Sleeve 1, poppet 2
Sleeve 1, poppet 4
Sleeve 3, poppet 4
Sleeve 3, poppet A
Sleeve 3, poppet B/C
1 : 1.05 AA = 0.95 AC AB = 0.05 AC 15° chamfer
1 : 1.05 AA = 0.95 AC AB = 0.05 AC 15° chamfer orifice
1 : 1.05 AA = 0.95 AC AB = 0.05 AC 45° chamfer
1 : 1.67 AA = 0.6 AC AB = 0.4 AC 45° chamfer
1 : 1.67 AA = 0.6 AC AB = 0.4 AC 45° chamfer safety spool
1 : 1.67 AA = 0.6 AC AB = 0.4 AC 45° chamfer throttle spool
D4S_UK.INDD RH
10-30
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Dimensions
Directional Seat Valve Series D4S (Denison)
D4S 03/06 T-body
D4S 06/10 L-body
Catalogue HY11-3500/UK
10
1)
Ports
Function
A B X1 Y1
inlet or outlet outlet or inlet external pilot port external drain 1)
D4S03 T-body G½" G½"
Port size D4S06 L-body D4S06 T-body G¾" G1" G¾" G1"
D4S10 L-body G1¼" G1¼"
G¼"
With VV01 only
Size 03 (T-body) 06 (T-body) Size 06 (L-body) 10 (L-body)
L1 53 66.5 L3 49 49.8
L2 92 117.5 B2 81 120.7
B1 85 136 B3 76 85.6
H1 27.5 38 B4 43 77.8
H2 21 28 H5 23 38.1
H3 59.5 93 H6 51 50.8
H7 81 96
H4 97.5 131 H8 119 134
D4S_UK.INDD RH
10-31
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Directional Seat Valve Series D4S (Denison)
Catalogue HY11-3500/UK
Dimensions
Dimensions D4S with VV01
10
D4S_UK.INDD RH
10-32
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Directional Seat Valve Series D4S (Denison)
Catalogue HY11-3500/UK
Dimensions Dimensions D4S position control
Function Supply voltage (Us) Supply voltage ripple Current consumption Residual voltage L-signal Output current (I) Protection class Ambient temperature Wire cross section
PNP, contact 10...30 10 max. 8 Us - 2.2 at lmax 200 IP67 [C°] -25...+70 [mm2] 3 x 0.5
[VDC] [%] [mA] [V] [mA]
Position control by proximity switch (incl. amplifier) Valve open: proximity switch activated. This proximity switch is pressure proof and has no wearing parts. Note Position control for D4S06 and D4S10 only. Dimensions D4S stroke limiter
10
Note: Stroke limiter not for use with D4S03, VV01, shuttle valve and positon control.
D4S_UK.INDD RH
10-33
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code Explanation (Examples)
Directional Seat Valve Series D4S (Denison)
D4S direct operated
D4S with solenoid valve VV01
10
D4S_UK.INDD RH
10-34
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Ordering Code Explanation (Examples)
Directional Seat Valve Series D4S (Denison)
D4S with position control
D4S with stroke limiter
10
D4S_UK.INDD RH
10-35
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Notes
10
D4S_UK.INDD RH
10-36
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Needle Valve Series MV / 9MV
Catalogue HY11-3500/UK
Characteristics / Ordering Code Manatrol needle valve, optional with 30° poppet, V-notch, or rectangular slot. The form of the throttle opening influences the accuracy of the flow setting, which depends on the pressure and viscosity. The needle is made of stainless steel and corresponds to a ring gap in the valve body.
Flow rate Q [l/min] = Kv · Kv ∆p [bar] γ [kg/dm3] (γ for mineral oil
∆p γ
from the table = spezific weight of the medium = 0.85 - 0.9)
∆p/Q curves
Technical data Size 200 400 600 800 1200 1600
Max.pressure Flow Max. cross. Kv factor Weight [bar] [l/min] sect. [cm²] ∆p valve [kg] steel brass ∆p 10bar 10bar open 350 140 11 0.07 3.5 0.13 350 140 25 0.14 6.3 0.31 350 140 65 0.37 18.5 0.54 350 140 105 0.55 27.5 0.95 350 160 0.90 45.7 1.58 210 190 1.10 54.6 1.9
Size and needle type
7 2 11
200-2 200-3 400-2
Ordering code
10
MV Thread type
Needle valve
Size and design
Body
Needle
Seal
Thread NPTF BSPP
Code omit 9 Straight way valve code 200 400 600 800 1200 1600
Size
Angle valve
1/8 1/4 3/8 1/2 3/4 1
code 261 461 661 861 1261 —
Code omit V
Seal NBR FPM
Needle Standard with omit 30° taper Fine due to 2) 2 V-notch Micro-fine due 3 2) to rect. slot
Code Code S B 1) 1)
Body Steel Brass
not for models MV 1200/1600 and design „61“ 2)
only for size 400
MV-9MV_UK.INDD RH
10-37
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Needle Valve Series MV / 9MV
Catalogue HY11-3500/UK
Dimensions Series MV*00 valve with connecting thread in-line
Size R* 2 1/8 4 1/4 6 3/8 8 1/2 12 3/4 16 1 * Pipe thread G or NPTF
H 24 33 38 51 54 60
H3 69 86 108 130 142 147
H2 64 81 100 117 128 133
H1 8 10.5 13 16 19 22.5
B 16 21 26 32 38 45
ØD1 15 20 23 29 36 36
L 38 51 64 67 83 108
ØD 45 51 64 83 98 98
SW 15.7 22.1 25.4 31.8 41.2 41.2
MVK sets MVK 2 MVK 4 MVK 6 MVK 8 MVK 12 MVK 12
Series MV*61 angle valve with connections at 90° angle
10
Size 2 4 6 8 12
R* 1/8 1/4 3/8 1/2 3/4
H 27 36 42 55 59
H3 72 90 111 134 147
H2 67 85 103 121 133
H1 20.6 27.7 34.8 42.7 41.1
B 16 21 26 32 38
ØD1 15 20 23 29 36
L 27 38 45 53 64
ØD 45 51 64 83 98
SW 15.7 22.1 25.4 31.8 41.2
* Pipe thread G or NPTF MV-9MV_UK.INDD RH
10-38
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Needle Valve Series N / 9N
Catalogue HY11-3500/UK
Characteristics / Ordering Code Manatrol stop and throttle valves with 2-stage needle cone. Fine adjustment for the first stage can be achieved with 3 rotations of the adjustment knob. The second stage with normal throttle characteristics is achieved with 3 further rotations. A cylindrical needle with a rectangular slot is provided to reduce the viscosity effect for sizes 200 up to 600. The flow is dependent on pressure and viscosity. ∆p γ
Flow rate Q [l/min] = Kv · Kv ∆p [bar] γ [kg/dm3] (γ for mineral oil
from the table = spezific weight of the medium = 0.85 - 0.9)
Specifications Return check poppet Nominal cracking pressure Operating temperature
0.4 bar -40°C to +121°C
Technical data (only for standard 2 stage needle) Size
Steel
400 600 800 1200 1600
350 350 350 350 210
Pressure [bar] Stainless 350 350 350 – –
Brass 140 140 140 140 35
Flow [l/min] 25 40 50 120 250
Max. cross section 0.13 0.22 0.28 0.70 1.48
Kv factor valve 6.3 11.2 13.9 35.4 75
Weight [kg] 0.22 0.6 0.63 1.04 2.13
Ordering code
N Thread type Code omit 9
Thread NPTF BSPP
Code 200 400 600 800 1200 1600
Size 1/8 1/4 3/8 1/2 3/4 1
Needle valve
Thread size
Body
Needle
Clamping screw
Seal Code omit V
Code Clamping screw Hexagon omit socket With knurled F knob Tamper-proof T
Code Body Code Steel S Brass B SS 1) Stainless steel 1)
Seal NBR FPM
omit 4 2)
only for sizes 400, 600, 800
2)
Needle Standard 2stage needle Micro-fine hollow needle with slot
only for sizes 200 to 600
N-9N_UK.INDD RH
10-39
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
10
Needle Valve Series N / 9N
Catalogue HY11-3500/UK
Characteristic Curves / Dimensions p/Q curves
Dimensions
Hexagon adjusting knob, standard for size 1600
10
Size 200 400 600 800 1200 1600
R* Threads 1/8 1/4 3/8 1/2 3/4 1
H3 39 46 55 69 86 124
H2 35 40 49 61 71 107
H1 8 10.5 13 16 19 22.5
B 16 21 26 32 38 45
L1 16 25 32 33 41 54
L 38 51 64 67 83 108
ØD 19 21 25 30 35 -
SW 47.8
* G or NPTF
N-9N_UK.INDD RH
10-40
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Throttle Check Valve Series F / 9F
Catalogue HY11-3500/UK
Characteristics / Ordering Code Manatrol throttle check valves of series F with fine adjustment of the flow rate for a defined flow direction. The built-in check valve allows free flow in the counter direction with little flow resistance. A 2-stage needle provides very exact setting of smaller flow rates with the first three rotations of the adjustment knob. After 3 more rotations, the valve is completely open. The valve setting can be locked using a locking screw. ∆p γ
Flow rate Q [l/min] = Kv · Kv ∆p [bar] γ [kg/dm3] (γ for mineral oil
from the table = spezific weight of the medium = 0.85 - 0.9)
Specifications Return check poppet Nominal cracking pressure Operating temperature
0.4 bar -40°C to +121°C
Technical data Size 200 400 600 800 1200 1600 2000 2400 3200
Pressure [bar] Stainless Brass Steel steel 350 – 140 350 350 140 350 350 140 350 350 140 210 – 140 210 – 35 210 – – 210 – – 210 – –
Max. flow [l/min ∆p10bar]
Opening [cm²]
Check Kv factor
11 25 40 50 120 250 250 250 250
0.14 0.37 0.62 0.86 1.18 2.23 3.45 4.40 5.11
6.7 18.6 30.4 43.4 60 111 174 225 259
Throttle surface Throttle v. open [cm²] Kv factor 0.066 0.13 0.22 0.28 0.70 1.48 1.48 1.48 1.48
3.3 6.3 11.2 14 35.4 75 75 75 75
Weight [kg] Steel
Brass
0.13 0.23 0.31 0.67 1.17 2.31 3.67 4.62 7.78
0.13 0.23 0.31 0.68 1.18 2.32 – – –
Ordering code
F Thread type Code omit 9
Thread NPTF BSPP
Code 200 400 600 800 1200 1600 2000 2400 3200
Size 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2
Throttle check valve
Thread size
Body
Needle
Clamping screw
10
Seal Code omit V
Code Clamping screw Hexagon omit socket With knurled F knob Tamper-proof T
Body Code Steel S Brass B 1) SS 2) Stainless steel 1) 2)
Seal NBR FPM
only for sizes 200 to 1600 available in sizes 400, 600 and 800
Code omit 4 3) 3)
Needle Standard 2stage needle Micro-fine hollow needle with slot
only for sizes 200 to 600
F-9F_UK.INDD RH
10-41
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Characteristic Curves / Dimensions
Throttle Check Valve Series F / 9F
Controlled flow vs. pressure drop needle fully open
Free flow vs. pressure drop needle fully open
Catalogue HY11-3500/UK
Dimensions
Hexagon adjusting knob, standard for sizes 1600 to 3200
10 Size 200 400 600 800 1200 1600 2000 2400 3200
R* 1/8 1/4 3/8 1/2 3/4 1 1 1/4 1 1/2 2
H3 39 46 55 69 86 124 130 137 146
H2 35 40 49 61 71 107 114 120 130
H1 8 10.5 13 16 19 22.5 29 35 44.5
B 16 21 26 32 38 45 58 70 89
L1 36 43 45 57 65 83 99 114 134
L 51 67 70 87 99 127 143 143 165
ØD 19 21 25 30 35 -
SW 47.8 -
T 9 13 13 16 17 20 21.5 23.5 25
* Pipe thread G or NPTF
F-9F_UK.INDD RH
10-42
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Flow Control Valve Series PCM / 9PCM
Catalogue HY11-3500/UK
Characteristics / Ordering Code Manatrol 2 way flow control valves for pressure compensated regulation of the flow rate. As a consequence of pressure changes, the set value can vary by ± 5% within the tolerance range. Viscosity changes have the same effect and are to be observed.
PCM
PCCM
Technical data Size 400 600 800 1200 1600
Flow control Max. press. ∆p Q* [l/min] [bar] [bar] 210 1 - 10 7 210 2 - 25 7 210 6 - 60 11 210 10 - 100 11 210 19 - 190 11
Check valve Qmax ∆p [l/min] [bar] 20 3 30 3 75 8 130 8 250 10
Weight [kg] 0.82 1.05 1.68 3.64 6.59
* Min. and max. flow rate
Ordering code
PC Thread Design Press. comp. flow type control valve Code omit 9
M Thread size
Body
Clamping screw
Seal
Design series
(is determined by factory)
Thread NPTF BSPP
Code omit V
Design Without check omit valve With check C valve
Code Clamping screw Hexagon omit socket With knurled F knob Tamper-proof T 2) 2) not available above size 1200
Code
Code 400 600 800 1200 1600
Seal NBR FPM
Size 1/4 3/8 1/2 3/4 1
Body Code Steel S SS 1) Stainless steel 1)
only for sizes 600 and 800
PCM-9PCM_UK.INDD RH
10-43
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
10
Characteristic Curves / Dimensions
Flow Control Valve Series PCM / 9PCM
∆p/Q curves
Size 400 - 1600
Catalogue HY11-3500/UK
p/Q control characteristic
Sizes 400, 600 and 1200: Pressure drop ∆p for flow through check valve in range Qmax / Qmin with each size
S i ze s 8 0 0 a n d 1 6 0 0 : Pressure drop ∆p for flow through check valve in range Qmax / Qmin with each size
The curves refer to hydraulic oil of 33 cSt / 50°C.
Dimensions
10 Hexagon adjusting knob, standard for size 1600
Size 400 600 800 1200 1600
R* 1/4 3/8 1/2 3/4 1
H3 69 80 103 128 175
H2 64 74 95 116 158
B 35 38 44 57 70
L1 16 18 22 28 33
B1 18 19 22 29 35
L2 92 106 125 149 176
ØD 21 25 30 35 -
SW 47.8
* Pipe thread G or NPTF PCM-9PCM_UK.INDD RH
10-44
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Check Valve Series C / 9C
Catalogue HY11-3500/UK
Characteristics / Ordering Code Manatrol check valves of series C for pipe mounting provide free flow in one direction and block flow in the counter direction. Depending on material specification, these valves are suited for use in hydraulic and pneumatic systems. Specific poppets and poppet guides ensure reliable functional integrity even at high flow rates and/or pulsations.
Technical data Size Max. operating pressure
steel brass
Pressure drop ∆p Flow Q
[bar] [bar] [bar] [l/min]
200 350 140 10 40
400 350 140 10 65
600 350 140 10 110
800 350 140 10 155
1200 350 140 1 112
1600 210 34 1 160
Ordering code
C Thread type
Code omit 9
Thread NPTF BSPP
Code 200 400 600 800 1200 1600
Size 1/8 1/4 3/8 1/2 3/4 1
Pipe mounting
Port size
Body
10
Opening pressure
Code Pressure [bar] 0.35 omit 4.5 65
Code S B
Body Steel Brass
C-9C_UK.INDD RH
10-45
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Characteristic Curves / Dimensions
Check Valve Series C / 9C
∆p/Q performance curves
Dimensions
10 Threaded connection R* G thread NPTF thread R 1/8" 1/8-27 NPTF R 1/4" 1/4-18 NPTF R 3/8" 3/8-18 NPTF R 1/2" 1/2-14 NPTF R 3/4" 3/4-14 NPTF R 1" 1-11-1/2 NPTF
Size C 200 C 400 C 600 C 800 C 1200 C 1600
Dimensions [mm] B 16 21 25 32 38 45
Weight [kg]
L 51 66 70 87 99 127
0.05 0.2 0.2 0.6 0.9 1.5
* For alternative thread design, see ordering code.
C-9C_UK.INDD RH
10-46
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Check Valve Series 6C
Catalogue HY11-3500/UK
Characteristics / Ordering Code Manatrol check valves of the series 6C have metric connecting threads according to ISO 6149. The valve provides the free flow in one direction and blocks flow in the counter direction.
Features • Connection according to ISO 6149 with conical surface for the O-ring • Metric connecting thread • Leak protection through O-ring seal between screw-in threaded joint and connecting thread
Drawing shown without O-Ring
Technical data Size Nominal pressure Flow Connecting thread Opening pressure Material
Seals*
[bar] [l/min] [bar] Body Poppet Guide Spring
616 350 65 M16 x 1.5 0.35 (standard) ASTM 12L14 steel ASTM 416 stainless steel ASTM 416 stainless steel ASTM 316 stainless steel Nitrile (NBR)
818 350 110 M18 x 1.5
1022 350 155 M22 x 1.5
1227 350 240 M27 x 2
* no seal at M27x2.0
10
Ordering code
Code 616 816 1022 1227
6
C
S
Metric port thread ISO 6149
Pipe mounting
Size
Steel body
Size M16 x 1.5 M18 x 1.5 M22 x 1.5 M27 x 2
6C_UK.INDD RH
10-47
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Check Valve Series 6C
Catalogue HY11-3500/UK
Dimensions
Size
Port thread A
6C616S 6C818S 6C1022S 6C1227S
M16 x 1.5 M18 x 1.5 M22 x 1.5 M27 x 2.0
Dimensions C 79.4 88.9 101.6 117.5
D 25.4 28.6 31.8 38.1
10
6C_UK.INDD RH
10-48
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Check Valve Series CP / 9CP
Catalogue HY11-3500/UK
Characteristics / Ordering Code Pilot operated check valves of the series CP allow free flow in one direction (A to B). The counter direction (B to A) is blocked. By applying pilot pressure, the poppet can be lifted from its seat against the pressure in port B. Thus flow in the counter direction is also possible. There are 1 and 2 stage poppets available with pilot ratios of 1 : 5 and 1 : 40, to suit different operating conditions.
Technical data Size Max. operating pressure Max. pilot pressure Flow Qmax at ∆p 2.7bar Nominal size Weight
[bar] [bar] [l/min] [kg]
600 210 210 30 3/8 4
1200 210 70 95 3/4 7
Pilot ratios Poppet 1 stage
Poppet 2 stage Surface ratio 40 : 1 (pilot spool decompression pin surface) for low shock or oscillation performance from decompression.
Surface ratio 5 : 1 (pilot spool-poppet surface) for quick response time without decompression.
Ordering code
CP
—
Thread Check Threaded type valve, pilot port operated Code omit 9
Thread NPTF BSPP
Code 600 1200
Size 3/8 3/4
S Port size
Steel body
10
M Pilot ratio
Steel poppet
Seal
Code omit V
Seal NBR FPM
Code Pilot ratio Stage 5 5:1 1 40 40 : 1 2
CP_UK.INDD RH
10-49
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Pilot Operated Check Valve Series CP / 9CP
Catalogue HY11-3500/UK
Characteristic Curves / Dimensions ∆p/Q performance curves
The curves refer to hydraulic oil of 33 cSt and 50°C.
Dimensions
10
Size A a, B L3 9CP600S G3/8 53.3 9CP1200S G3/4 63.5
B1 50.8 63.5
B2 25.4 31.8
H1 38.1 50.8
H 76.2 101.6
L4 25.4 31.8
L7 76.2 91.2
H4 10.4 10.7
L L1 120.7 10.7 152.4 11.43
H2 9.4 11.2
H3 66.5 90.4
L6 9.4 11.2
L5 111 141.2
Ød 9.1 10.7
W 7.9
CP_UK.INDD RH
10-50
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Hydraulically Pilot Operated Check Valve Series RH
Catalogue HY11-3500/UK
Characteristics Pilot operated check valves series RH allow free flow in one direction (B to A). The counter flow is blocked (A to B). By applying pilot pressure the ball can be lifted from its seat and allow flow from A to B. Most common use: • Keeping cylinders leak-free in position, when spool type directional control valves are used • Return line discharge, when return flow exceeds functional limits of directional control valve at differential cylinders • As hydraulically activated drain or circulation valve The valves are available without and with hydraulic predischarging.
Without pre-discharging These valves have a ball as valve element, which quickly enables the full flow cross-section proportionally during pilot operation. A metering position in the pilot port dampens the control movement of the pilot spool so that pressure shocks (unloading shocks) are mostly suppressed.
With pre-discharging For valves with pre-discharging a spherical polished valve spool (seat valve function) is built-in instead of a ball.The additional check valve achieves a pre-opening which provides shock-free unloading of the fluid, especially at high working pressure and large volumes.
Connection for pilot line
Connection for pilot line
10 Technical data Code Max. operating pressure Flow approx. Pilot flow volume Pipe connections DIN ISO 228/1 A, B Pipe connections DIN ISO 228/1 Z Weight Mounting Mounting position Fluid Viscosity recommended Viscosity permitted Temperatures
RH [bar] [l/min] [cm³]
[kg]
[cSt]/[mm2/s] [cSt]/[mm2/s] [°C]
1 2 3V 700 700 500 15 35 55 0.15 0.22 0.4 G 1/4 G 3/8 G 1/2 G 1/4 G 1/4 G 1/4 0.4 0.4 0.6 Freely suspended in the pipeline unrestricted Hydraulic oil 10...68 mm²/s (ISO VG 10 to 68 as per DIN 51 519) 10...500 4...1500 Fluid and ambient: -40...+80; observe viscosity range!
4V 500 100 1 G 3/4 G 1/4 1.3
RH_UK.INDD RH
10-51
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Hydraulically Pilot Operated Check Valve Series RH
Catalogue HY11-3500/UK
Ordering Code / Characteristic Curves Ordering code
RH Flow
Check valve, hydr. pilot operated Code 1 2 3 4
Predischarging
Code Pre-discharging with V* without omit * only for sizes 3 and 4
Flow [l/min] 15 35 55 100
Pilot pressure pSt for pilot operation of the main valve (pB = 0 bar)
Pilot pressure pSt for pilot operation of pre-discharging
for keeping open pSt pB ∆p k
10
pB + ∆p + k [bar] pressure on side B [bar] flow resistance A to B as per ∆p/Q performance curve 10 at RH 1 and RH 2 7 at RH 3 V 8 at RH 4 V
Performance curves ∆p/Q (valid for flow polarity B to A and pilot operated direction A to B) Opening pressure B to A 0.2...0.3 bar Oil viscosity during the measurement, 60 mm²/s For viscosities over approx. 500 mm²/s, a strong ∆p-increase is to be expected for smaller types (RH1...RH3).
RH_UK.INDD RH
10-52
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Hydraulically Pilot Operated Check Valve Series RH
Catalogue HY11-3500/UK
Dimensions
Type RH 1 RH 2 RH 3 V RH 4 V
Port * A, B G 1/4 G 3/8 G 1/2 G 3/4
Z G 1/4 G 1/4 G 1/4 G 1/4
L
a
b
WW
84 90 100 126
31.5 32 36.5 45
27 28.5 31 35.5
24 27 32 41
* as per DIN 228/1, suitable for pipe connections with thread studs form B as per DIN 3852 page 2.
10
RH_UK.INDD RH
10-53
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Notes
10
RH_UK.INDD RH
10-54
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Valves for Pipe Mounting Accessories
Catalogue HY11-3500/UK
Plugs
Description Plug DIN 43650, design type AF, protection class IP 65 Voltages up to 250 V
Threaded cable joint
Body colour coding
Figures switching
Order no.
PG 9
black, B grey, A
Fig. 1
5001710 5001711
PG11
black, B grey, A
Fig. 1
5001716 5001717
Other plugs on request
10
access10.INDD RH
10-55
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index
Catalogue HY11-3500/UK
Notes
10
access10.INDD RH
10-56
Home
Content catalogue Content chapter
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Ordering Code
Index