Characteristics Seat valves series D5S are designed for directional control functions. They enable individual hydraulic solutions for nominal flow up to 800 l/min due to a large variety of poppets, springs and covers, including shuttle valves, stroke limiters, solenoid valves (VV01) and position control. A complete program is offered under the Denison brand: subplate mounted valves (D4S - chapter 6), SAE flange valves (D5S - chapter 9), pipe mounted valves (D4S - chapter 10), slip-in cartridges (CAR - on request). Features • Leak-free seat valve design • 2- and 3-port bodies • SAE61 flange • Numerous pilot options • 6 poppet types • 4 sizes, SAE 3/4“, 1“, 1 1/4“, 1 1/2“

D5S 2-port

D5S 2-port

D5S 3-port

D5S 2-port

D5S 3-port

D5S 3-port

9

D5S_UK.INDD RH

9-35

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Directional Seat Valve Series D5S (Denison)

Catalogue HY11-3500/UK

Ordering Code

D5S Seat valve

Nominal size

Code 06 08 10 121)

Port size SAE ¾" SAE 1" SAE 1¼" SAE 1½"

1)

Body

Pilot body Pilot configuration cap

Spool type

Sleeve

Spring

Code

Body

5

3-port

7

2-port

8

2-port

Code

013 Code 1 5

Ports Seat entry, A; X1, Y1, M = G¼" Seat entry, A; X1, Y1 = G¼" Annular entry, B; X1, Y1 = G¼"

Ports

X1 — —

Code omit 09 10 11 12

Y1 VV01 — — —



1 2 4 A2) B2) C2)

Options

Options Standard Position control with protection Seals NBR FPM

Switching type Standard VV01 with manual override de-energized: power comp. open VV01 without manual override VV01 with manual override de-energized: power comp. closed VV01 without manual override

CA

Shuttle valve

DA

Shuttle valve

CB CD DB DD

VV01 code 09 and shuttle valve code CA VV01 code 11 and shuttle valve code CA VV01 code 09 and shuttle valve code DA VV01 code 11 and shuttle valve code DA VV01 code 10 and shuttle valve code CA and position BH control 3) with amplifier VV01 code 12 and shuttle valve code CA and position BK control 3) with amplifier VV01 code 10 and shuttle valve code DA and position BN control 3) with amplifier VV01 code 12 and shuttle valve code DA and position BQ control 3) with amplifier BC VV01 code 10 and position control 3) with amplifier BE VV01 code 12 and position control 3) with amplifier BA Position control 3) with amplifier BF Position control 3) with amplifier and shuttle valve code CA BL Position control 3) with amplifier and shuttle valve code DA 3) Position control for D5S08/10 only. Spring 2 or 4. Spool A and sleeve 3.



— — — — — — orifice Ø 1.2

Code Sleeve 1 AA=95%, AB=5% 3 AA=60%, AB=40%

Code

Seals

Code Solenoid voltage omit Standard G0R 12V= G0Q 24V= GAR 98V= GAG 205V= W06 115V / 50Hz W07 230V / 50Hz

Pilot oil line in body internal from A internal from B internal from A and B external from X1 int. from B, ext. from X1

Body

Design series Code omit

X Y Z X-Y Standard 1 2-/3-port Pilot oil = pilot drain 2 2-/3-port Pilot oil = pilot drain 3 2-port Pilot oil = pilot drain With solenoid valve (VV01) 4 2-/3-port Internal to B 5 2-port Internal to B 6 2-/3-port Ext. out of cap 7 2-port Ext. out of cap With stroke limiter (not for D5S06) A 2-/3-port Pilot oil = pilot drain — B 2-/3-port Pilot oil = pilot drain — — C 2-port Pilot oil = pilot drain — open bore closed bore Note: Combination examples at the end of chapter

2)

Switching Solenoid voltage type

D5S 3-port only

Code 1 2 3 4 5

9

B

Size

Poppet type Sleeve With closed bottom and 15° chamfer (pZ max. 1 = pA +20bar With 0.8 dia. orifice at the bottom and 15° 06 1 chamfer With 1.2 dia. orifice at the bottom and 15° 08, 10 1 chamfer 06, 08,10,12 With closed bottom and 45° chamfer 1, 3 08, 10, 12 Safety spool (for end position control only) 3 08, 10, 12 Throttle spool, 10° chamfer 3 08, 10, 12 Throttle spool, 3° chamfer 3 06, 08,10,12

Springs 2, 3, 4 and 6 only

Code 1 2 3 4 5 6 7

Spring (approx. cracking pressure [bar]) Sleeve Code 1 Sleeve Code 3 A -> B A -> B B -> A D5S06 D5S08/12 D5S06 D5S08/12 D5S06 D5S08/12 2.8 3.5 6.5 6.5 9.5 11.0 0.5 0.5 1.0 1.0 1.5 1.7 0.3 0.3 0.6 0.6 0.9 1.0 2.2 2.2 4.0 3.5 5.5 6.0 — 9.0 — 16.0 — 28.0 1.2 1.2 2.0 2.2 3.0 3.8 3.0 — 8.0 — 12.0 —

D5S_UK.INDD RH

9-36

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Directional Seat Valve Series D5S (Denison)

Catalogue HY11-3500/UK

Technical Data Technical data General Size Mounting Mounting position Ambient temperature Weight

06 08 Flanged according to SAE 61 unrestricted [°C] -20...+50 [kg] 3.6 4.1 [kg] 3.4 4.4

D5S 2port D5S 3port

Hydraulic Max. operating pressure SAE61 Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Electrical (solenoid) Duty ratio Response time Supply voltage Tolerance supply voltage Power consumption hold in rush Max. switching frequency Solenoid connection Protection class Coil insulation class

10

12

5.4 5.0

— 7.8

350 350 280 30 30 30 180 360 600 Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 10...650 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

210 30 800

[bar] Ports A, B Port Y1 [l/min]

[%] 100 [ms] Energized / De-energized AC: 20/18 , DC: 46/27 G0R 12V = +5...-10 31 31

G0Q 24V = +5...-10 31 31

GAR 98V = +5...-10 31 31

GAG 205V = +5...-10 31 31

W06 W07 150 at 50Hz 230 at 50Hz +5...-10 +5...-10 78 78 264 264

AC: up to 7200, DC: up to 16000 switchings/hour Connector as per EN175301-803 IP65 in accordance with EN 60529 (plugged and mounted) H (180 °C)

9

D5S pilot configuration 3-port

2-port: Seat Entry

2-port: Annular Entry

D5S_UK.INDD RH

9-37

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Directional Seat Valve Series D5S (Denison)

Catalogue HY11-3500/UK

Characteristic Curves D5S 2-port

D5S 3-port

9

Fluid viscosity 38cSt at 50 °C

Selection of Cartridges Sleeve 1, poppet 1

Sleeve 1, poppet 2

Sleeve 1, poppet 4

Sleeve 3, poppet 4

Sleeve 3, poppet A

Sleeve 3, poppet B/C

1 : 1.05 AA = 0.95 AC AB = 0.05 AC 15° chamfer

1 : 1.05 AA = 0.95 AC AB = 0.05 AC 15° chamfer orifice

1 : 1.05 AA = 0.95 AC AB = 0.05 AC 45° chamfer

1 : 1.67 AA = 0.6 AC AB = 0.4 AC 45° chamfer

1 : 1.67 AA = 0.6 AC AB = 0.4 AC 45° chamfer safety spool

1 : 1.67 AA = 0.6 AC AB = 0.4 AC 45° chamfer throttle spool

D5S_UK.INDD RH

9-38

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Catalogue HY11-3500/UK

D5S with Vent Valve

Directional Seat Valve Series D5S (Denison)

Example pilot oil external from X1, pilot drain internal out of B

Function Solenoid de-energized: pilot oil from X1 to Z blocks the connection from A to B or B to A. Solenoid energized: pilot pressure from X1 is blocked in the VV01. The oil in Z is internally drained to port B. Allowing flow from A to B, while B to A remains blocked.

D5S with VV01 dimensions

9

D5S_UK.INDD RH

9-39

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Catalogue HY11-3500/UK

D5S with Position Control

Directional Seat Valve Series D5S (Denison)

D5S with position control Position control by proximity switch (incl. amplifier). Valve open: proximity switch activated. This proximity switch is pressure proof and has no wearing parts. Note: Position control for D5S08 and D5S10 only.

Example D5S 2 port

D5S with position control dimensions

Technical data (proximity switch) Function Supply voltage (Us) Supply voltage ripple Current consumption Residual voltage L-signal Output current (I) Protection class Ambient temperature Wire cross section

9

PNP, contact 10...30  10 max. 8 Us - 2.2 at lmax  200 IP67 [C°] -25...+70 [mm2] 3 x 0.5

[VDC] [%] [mA] [V] [mA]

D5S_UK.INDD RH

9-40

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

D5S with Stroke Limiter

Directional Seat Valve Series D5S (Denison)

D5S stroke limiter

Stroke limiter dimensions

Catalogue HY11-3500/UK

Example: D5S08-54A-... D5S10-54A-... D5S12-54A-...

X1 = external pilot-oil (optional) Note: Stroke limiter not for use with D5S06, solenoid valve VV01, shuttle valve and position control.

D5S with shuttle valve Dimensions

9

Shuttle valve only in connection with vent valve VV01.

D5S_UK.INDD RH

9-41

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Ordering Code Explanation (Examples)

Directional Seat Valve Series D5S (Denison)

D5S 2-port Seat entry

Annular entry

Stroke limiter D5S 2-port Seat entry

Annular entry

D5S 3-port

Stroke limiter D5S 3-port

Catalogue HY11-3500/UK

9

D5S_UK.INDD RH

9-42

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Ordering Code Explanation (Examples)

Directional Seat Valve Series D5S (Denison)

D5S 2-port with solenoid valve VV01 Seat entry

Annular entry

Catalogue HY11-3500/UK

9 D5S 2-port with with solenoid valve VV01 and shuttle valve Seat entry

Annular entry

D5S_UK.INDD RH

9-43

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Catalogue HY11-3500/UK

Ordering Code Explanation (Examples)

Directional Seat Valve Series D5S (Denison)

D5S 3-port with solenoid valve VV01

9 D5S 3-port with with solenoid valve VV01 and shuttle valve

D5S_UK.INDD RH

9-44

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Ordering Code Explanation (Examples)

Directional Seat Valve Series D5S (Denison)

D5S 2-port position control Seat entry

Annular entry

Catalogue HY11-3500/UK

9 Seat entry

Annular entry

D5S_UK.INDD RH

9-45

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Ordering Code Explanation (Examples)

Directional Seat Valve Series D5S (Denison)

D5S 3-port position control Seat entry

Annular entry

Seat entry

Annular entry

Catalogue HY11-3500/UK

9

D5S_UK.INDD RH

9-46

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Dimensions

Directional Seat Valve Series D5S (Denison)

Dimensions D5S 2-port Seat entry

Annular entry

Catalogue HY11-3500/UK

9

NG 06 08 10

l1 77 94 94

l2 101.0 120.5 128.0

l3 22.2 26.2 30.2

Ports

Function

A B X1 Y1

Inlet or outlet Outlet or inlet External pilot port External pilot drain

b1 60 60 75

h1 37 45 48 D5S06 ¾" SAE-61 ¾" SAE-61

h2 47.6 52.4 58.7

h3 90 96 109 Port size D5S08 1" SAE-61 1" SAE-61

h4 127.6 133.6 146.6

d1 19 25 32

d2 10.5 10.5 12.5

D5S10 1¼" SAE-61 1¼" SAE-61

G¼"

D5S_UK.INDD RH

9-47

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Directional Seat Valve Series D5S (Denison)

Catalogue HY11-3500/UK

Dimensions Dimensions D5S 3-port

9

NG 06 08 10 12

l1 49 55 57 37

Ports

l2 47.6 52.4 58.7 69.8

l3 56 58 64 55

l4 63 65 61 93

Function

A (2x) Inlet or outlet B Outlet or inlet X1 1) External pilot port Y1 External pilot drain M Pressure gauge 1) closed when supplied

b1 22.2 26.2 30.2 35.7

b2 60 60 75 80

h1 41 47 65 73

h2 47.6 52.4 58.7 69.8

h3 28 29 36 72

h4 22.2 26.2 30.2 35.7

h5 82 103 113 140

h6 119 141 150 178

d1 3/8" UNC 3/8" UNC 7/16" UNC 1/2" UNC

t1 20 23 22 27

d2 19 25 32 38

d3 10.5 10.5 12.5 13.5

Port size D5S06 ¾" SAE-61 ¾" SAE-61

D5S08 1" SAE-61 1" SAE-61

D5S10 1¼" SAE-61 1¼" SAE-61

D5S12 1½" SAE-61 1½" SAE-61

G¼"

D5S_UK.INDD RH

9-48