1 Fan Blade. 1 Instruction Sheet. 5. Remove ice tray and glass shelf from freezer compartment. Remove screw securing air tower. Pull out air tower to remove.
Instruction Sheet for Freezer Compartment Frost Kit Kit Contents: 1 Silicone Caulk 1 Gasket Material 1 Fan Blade 1 Instruction Sheet
5. Remove ice tray and glass shelf from freezer compartment. Remove screw securing air tower. Pull out air tower to remove. See Figure 3.
WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
Air tower glass shelf
ice tray
1. Unplug refrigerator or disconnect power. 2. Apply silicone to area between the liner and cabinet flange on all 4 sides of freezer and refrigerator compartments. See Figure 1.
figure 3
6. Cut gasket material supplied in kit and fit to bottom of air tower as shown in Figure 4.
potential gaps between the liner and cabinet flanges gasket material
figure 4
7. Remove the existing evaporator fan motor blade and replace it with the one in the kit. Install the blade up to the stop on the shaft for proper installation.
figure 1
3. Clean up excessive silicone applied using ethyl alcohol and a clean cloth. See Figure 2.
8. Replace air tower and verify the bottom of the tower is completely in position to ensure sealing. 9. Replace all parts and panels.
WARNING
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong.
figure 2
Do not use an adapter.
4. Verify silicone fills the gaps between the liner and cabinet flange on top and sides of freezer compartment and is uniform and there are no holes, helping prevent air infiltration. See Figure 1 and Figure 2.
Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. 10. Plug in refrigerator or reconnect power.
Fiche d’instructions de l’ensemble pour congélateur L’ensemble contient : 1 tube de silicone 1 produit d’étanchéité 1 pale de ventilateur 1 fiche d’instructions
5. Enlever le casier à glaçons et la tablette en verre du congélateur. Retirer les vis maintenant en place la tour de circulation d’air. Tirer sur la tour pour l’enlever. Voir la Figure 3.
AVERTISSEMENT Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien.
Tour de circulation d’air
Casier à glaçons
Replacer pièces et panneaux avant de faire la remise en marche. Le non-respect de ces instructions peut causer un décès ou un choc électrique.
Tablette en verre
figure 3
6. Couper le produit d’étanchéité inclus dans l’ensemble et le placer au bas de la tour de circulation d’air comme indiqué à la Figure 4.
1. Débrancher le réfrigérateur ou déconnecter la source d’alimentation. 2. Appliquer le silicone sur la zone entre la cavité et le contour de l’appareil, sur les 4 côtés du congélateur et du réfrigérateur. Voir la Figure 1.
Produit d’étanchéité
Espace possible entre la cavité et le contour de l’appareil
figure 4
7. Retirer les pales existantes du moteur de ventilateur de l’évaporateur et les remplacer par celles de l’ensemble. Effectuer une bonne installation en insérant les pales jusqu’à l’arrêt sur l’arbre. 8. eplacer la tour de circulation d’air et vérifier que sa partie inférieure est bien positionnée pour assurer l’étanchéité. 9. Réinstaller l’ensemble des pièces et panneaux.
figure 1
AVERTISSEMENT
3. Enlever l’excédant de silicone en utilisant un tissu propre et de l’éthanol. Voir la Figure 2.
Risque de choc électrique Brancher sur une prise à 3 alvéoles reliée à la terre. Ne pas enlever la broche de liaison à la terre. Ne pas utiliser un adaptateur. Ne pas utiliser un câble de rallonge. Le non-respect de ces instructions peut causer un décès, un incendie ou un choc électrique.
Transfer tech sheet (and bag) over to new single metal access panel. Place new panel on dishwasher and align holes in panel with holes in clips. 4. Secure single metal access panel to dishwasher using the. 2 screws supplied. 5. Replace all parts and
... en maintenance comporte une gâche en plastique, celle-ci doit être remplacée par une gâche métallique et le joint d'étanchéité doit également être remplacé.
for Strike Plate and Latch Assembly kit. 1. Unplug dishwasher or ... may not be designed to function with the new latch design in an optimal fashion that could ...
causer un décès ou un choc électrique. Replacer pièces et ... S'assurer de déconnecter la source de courant électrique avant ... composant. FIGURE 1. AXE EN ...
6 oct. 2005 - Description: Switch, Dual Element Markings ... To avoid risk of electrical shock, personal injury or death; disconnect electrical power before ...
6 juin 2018 - The Caleffi 573 series Is certified by ICC-ES to be in compliance with ... ATTENTION: Si Disconnecteur n'est pas installé, mis en service et ...
1 janv. 2012 - APPLICATION: The Taco SmartPlus is designed to increase hot water comfort while con- serving water and energy. By recirculating âcooledâ hot water back to the water heater, the wait for hot water is decreased to seconds. BENEFITS:
1. Unplug range or disconnect power before servicing. 2. Lay moisture barrier on flat surface oriented as shown in. Figure 1. WARNING. Electrical Shock Hazard.
Déconnecter la source de courant électrique avant l'entretien. Le non-respect de ces instructions peut causer un décès ou un choc électrique. Replacer pièces ...
7 avr. 2016 - Install all other system components as shown in the piping diagram in Figure ... Change the position of the toggle switch on the circuit board to.
Disconnect the connector from damper assembly. See Figure 10. 14. Pull christmas tree clip. See Figure 10 and Figure 11. â 2 â. W10885624 A. (continued). 9. Turn ice maker assembly over and remove three screws from bottom of impinger to release i
14 mai 2018 - Function. The Z-one, a two-position spring return zone valve, is used in heating and air-conditioning systems. The Z-one series consist of a Z1 ...
Fermez l'alimentation en eau du réfrigérateur. 3. Enlevez le couvercle du tuyau de remplissage (3 vis). Voir Figure 1. 4. Déterminez le genre de tuyau utilisé.
31 janv. 2019 - variability of mineral content found in untreated site water which provides more reliable dosing .... demineralized water is lost. If the system was ...
19 juil. 2018 - This item is designed for use in closed hydronic systems. Do not use in plumbing applications. This item does not meet the low-lead plumbing ...
Libérer l'agrafe arrière/gauche. Voir la Figure 9. ... Poursuivre l'opération depuis le côté gauche vers le côté droit - insérer une main entre le couvercle du réservoir d'eau et la doublure .... Accéder à l'interface-utilisateur et régler la tempéra