Pilot Operated Check Valve Series CPOM Characteristics

When the valve poppet is open, the large cross-section allows high flow rates at low differential pressure. • Different control ratios can be chosen with the NG6.
420KB taille 185 téléchargements 504 vues
Pilot Operated Check Valve Series CPOM

Catalogue HY11-3500/UK

Characteristics Pilot operated check valves from the Parker Manapak series CPOM are sandwich plate valves designed for stacking beneath a directional valve with a standardised mounting pattern. Depending on the function required, one or two pilot operated check valves are arranged in the ports A and/or B. The free flow direction is always from the valve side to the manifold side.

Function The check valves open when flowing to the consumer side, where the opposing check valve is hydraulicallymechanically pilot operated simultaneously by a control spool, and thus the return flow is enabled from other consumer sides.

Features • The valve bodies of the Parker Manapak valve series CPOM are made of steel. • The valve poppet is precisely guided into the steel sleeve and ensures a good seal on the seat. • When the valve poppet is open, the large cross-section allows high flow rates at low differential pressure. • Different control ratios can be chosen with the NG6 and NG10 valves. • Pre-opening for CPOM*HT to achieve smooth opening. CPOM2 / CPOM3

CPOM3

Technical data Port size Mounting pattern Series Working pressure Opening pressure Control ratio Weight

DIN

NG06

CPOM2 [bar] 350 [bar] 1.0 1 : 3 or 1:7 [kg] 1.8

NG10 NG16 ISO 4401 CPOM3 CPOM4 350 350 0.8 2.0 1 : 3 or 1 : 2.4 1 : 6.5 4.0 7.4

NG25 CPOM6 210 0.4 1:3 9.5

CPOM4 / CPOM6

CPOM_UK.INDD RH

7-73

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

7

Pilot Operated Check Valve Series CPOM

Catalogue HY11-3500/UK

Ordering Code Without pre-opening

V

CPOM Hydraulically operated check valve pilot ratio 3 : 1 Code 2 3 6 Code AA BB DD

Size

Poppet style

Cracking pressure

Seal FPM

Design series (not required for ordering)

Size NG06 NG10 NG25

Code

Pressure

Size

omit

1.0 bar

2, 3, 6

25

2.5 bar

2

50

5.0 bar

2

Connection only A only B A and B

70

7.0 bar

2

Code

Size 2 3 4

Ratio 7:1 6.5 : 1 13 : 1

With pre-opening

CPOM

7

Hydraulically operated check valve Code 2 3 4

Size NG06 NG10 NG16

Code AA BB DD

Connection only A only B A and B

Size

Poppet style

HT

V

Pilot ratio

Seal FPM

Design series (not required for ordering)

HT

CPOM_UK.INDD RH

7-74

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Performance Curves

Pilot Operated Check Valve Series CPOM

∆p/Q performance curves CPOM2

CPOM3

CPOM2 (type HT)

CPOM3 (type HT)

Catalogue HY11-3500/UK

7

CPOM_UK.INDD RH

7-75

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Performance Curves

Pilot Operated Check Valve Series CPOM

∆p/Q performance curves CPOM4 (type HT)

CPOM6

Catalogue HY11-3500/UK

7

CPOM_UK.INDD RH

7-76

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Catalogue HY11-3500/UK

Dimensions

Pilot Operated Check Valve Series CPOM

CPOM2

Seal kit CPOM2 Seal Order code V SK-CPOM2-V-11

CPOM3

7

Seal kit CPOM3 Seal Order code V SK-CPOM3-V-11 Note: The O-ring plate for sealing the connecting surface of the manifold side is included. The O-ring plate and the positioning pin are always mounted on the manifold side. CPOM_UK.INDD RH

7-77

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Catalogue HY11-3500/UK

Dimensions

Pilot Operated Check Valve Series CPOM

CPOM4

Seal kit CPOM4 Seal Order code V SK-CPOM4HTV

7

CPOM6

Seal kit CPOM6 Seal Order code V SK-CPOM6-V-20 Note: The O-ring plate for sealing the connecting surface of the manifold side is included. The O-ring plate and the positioning pin are always mounted on the manifold side. CPOM_UK.INDD RH

7-78

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany