MicroSolvTech.com ... The HPLC Performance Qualification (PQ) Kit is designed to allow you to test and ... A dedicated, premium test column ... Software automatically compiles information, calculates and graphs results; print out and sign.
HPLC Performance Qualification System What is the PQ Kit?
The HPLC Performance Qualification (PQ) Kit is designed to allow you to test and document your HPLC systems using NIST-Traceable standard reference materials. A dedicated, premium test column is provided with the kit to ensure the scientific integrity of the test results. Both Isocratic and Gradient Systems can be qualified, with Variable Wavelength or Diode Array detectors. The PQ System is comprised of 4 major components: • A series of NIST-Traceable calibration solutions, with Certificate of Analysis • The PQ Test Column — Pre-Tested for the test protocols with a Certificate • A Validated Excel™ based software template (protected) to compile, calculate and graph the test results • A series of Test Protocols, which can be freely incorporated into your internal SOP’s
What Does it Test?
The PQ System tests your HPLC for the following performance characteristics: SYSTEM TESTS HPLC Extra-Column Instrument Volume Gradient Dwell Volume
DETECTOR Detector Short-Term Dynamic Noise Detector Wavelength Accuracy Primary Standard - up to 14 from 241 nm - 641 nm Secondary Standard @ 273 nm Detector Linearity over 3 Orders (equivalent to 100% - 0.1%)
The HPLC PQ Kit is:
Compliant - Build cGMP Compliance and NIST-Traceability into your laboratory qualification system. The validated software is readily incorporated into your current document control system for 21 CFR 11 compliance. Scientific- Protocols are scientifically sound, with full discussion and justification for their design. Universal- Standard test solutions, dedicated HPLC column and test protocols can help evaluate Method Transfer and Reproducibility issues. Rapid-Isocratic data in 3 hours (Automated & Gradient qualifications in about 45 min. per solvent pair.) Easy- Pre-made solutions: a simple binary mobile phase is all that is needed to start your run. Software automatically compiles information, calculates and graphs results; print out and sign. Flexible- Use included protocols, adapt to internal SOP or use as a training tool. Economical- Very low cost per qualification. Replacement solutions available. Customer support is always available at no charge.
Cat. No.
Description
49101-10
MicroSolv PQ Kit™ for HPLC Compliance, complete with special HPLC Column, NIST Traceable Solutions, Accessories, Certificate of Analysis, Chromatograms and CD-ROM with Software, Complete Instructions and Forms
49101-25S
Replacement Solutions for PQ Kit™. Includes, Wavelength Calibration Solution 30ml, Gradient Visualization Solution 50ml, Resolution Test Mixture 30ml, 5 Linearity Solutions 30ml and 1 Linearity Solution 50ml and a Certificate of Analysis. All solutions are NIST Traceable.
49101-50C
Replacement PQ Kit™ HPLC Column. Dedicated column for specialized use with the PQ Kit™
PQA-HOX-01 Wavelength Calibration Solution for UV-Vis Detectors. 4% Holmium Oxide by weight in 10% Perchloric Acid 30ml.
MICROSOLV TECHNOLOGY CORPORATION 103 Brighton Ave. • Long Branch, NJ 07740 USA • 732-229-3400 • www.MicroSolvTech.com
Data System, and following your company's internal SOP's regarding documentation. ... to your laboratory, with your company's name and other information, ...
Cogent-HPLC.com. HSQ⢠Kit for HPLC ... HPLC Performance Qualification test kit, complete ... Test Kits. For more information visit www.mtc-usa.com. WHAT IS THE HSQ⢠KIT? ... information, calculates and graphs results; print out and sign.
Phase (HILIC). Max Pressure. 8,000 psi 8,000 psi. Max Temp. 125°C. 125°C. pH Range. 2 - 10.1. 2 - 8.0. 40mm x 2.1mm Column Shown. For more information ...
In the 15th to 17th century more sailors died of scorbut than of any other disease. The food provided on board contained nearly no Vitamin C. In the. 16th century the importance of Vitamin C supplied by citrus fruits in healing scorbut was discovered
To Order Call: 1-732-578-1777 or Order online @ www.mtc-usa.com. 2. For Most ... Terms are net 30 days for cus- .... These center .... Q Analytical Glossary.
operation after routine preventative maintenance of individual components, after major .... Materials and Methods are described in separate sections. ... After flow qualification, the Resolution Test Mixture is injected into a stable HPLC ...... tern
Section 3—Receiving, Handling, and Storage. 2. 45123-981-01 ... Use Class J or R fuses if the plug-in unit is installed on circuits capable of delivering more ...
For use in water circuits and swimming pools. ... compatible with inorganic builders and nonionic surfactants ... 5.2.1 Algaestatic efficacy according to OECD 201:.
Tighten phase lug and neutral lug clamping screws to 375 lb-in. (42 N•m) .... When relocating the plug-in unit, inspect the joint compound on the plug-in jaws for ...
and a Agilent 6210 MSD TOF mass spectrometer was used (Figure 2). Experimental ... LC/TOF instrument configuration. Figure 1. Topology Of Silica B And ...
A CD with the Excel-based Template program, along with electronic copies of the manuals and ... For manual flow rate qualification, a typical range for an analytical HPLC ..... enable the Macros, by setting the security level to Low or Medium.
Description. APP A44. APPLICA. TION. NOTES. Method Conditions. Column: ... retention higher percentages of water in the mobile phase can be used. The diminished hydrophobicity is shown in Table 1. For more information visit www.
The simultaneous elution of the same sample injected at the same time via 4 injection valves was ... Eluent : gradient in 18min, water/ACN (65:35) to (50:50).
elution order of compounds with aqueous mobile phases, these columns will ... columns is their ability to perform the âreverse gradientâ and to separate and ...
Retires. B reaks. Hand-to-hand Combat hand Combat. Comb at T o H it modifiers. Comb at T o H it modifiers. (hit on roll of 4 + ). +1 Charging. -1 Shaken or D ...
40018-75P. Cogent Bidentate⢠C18 HPLC Column, 4µm \,100A 4.6mm x 75mm. Cat. ... Solvent A: 100% DI water + ... 1mg of the compound dissolved in 1 mL.
tion There is no need to filter any of the CElixir Solution (A) before coating ... celerator Solution (B) can be used as your sample diluent but you must be careful to ...
Welcome to the PQ Kit! These instructions are designed to help you to quickly familiarize yourself with the procedures needed to fully qualify your HPLC using ...
Mass Spec: Atmospheric Pressure. Chemical Ionization in positive mode: APCI+ Single Ion Monitoring. Discussion. Two proprietary compounds, which are ...
fluorescence, or electrochemical detectors can be selected according to your needs. Dual detectors in tandem can be used for the simultaneous analysis of.