precautions to be observed before and during servicing to avoid ...

Control Panel and Electronic Control Test. The built-in microwave oven is provided with a self-diagnostic routine that can be accessed through the control panel.
346KB taille 13 téléchargements 884 vues
Tech Sheet

Do not discard

WARNING

Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY a. Do not operate or allow the oven to be operated with the door open. b. Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: 1. Interlock Operation 2. Proper Door Closing 3. Seal and Sealing Surfaces (Arcing, Wear and Other Damage) 4. Damage to or Loosening of Hinges and Latches 5. Evidence of Dropping or Abuse c. Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, waveguide or transmission line, and cavity for proper alignment, integrity and connections.

W10197623A / 461969469781

d. Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in service manual before the oven is released to the owner. e. A microwave leakage check to verify compliance with the Federal Performance Standard (CSA in Canada) should be performed on each oven prior to release to the owner. f. Do not attempt to operate the oven if the door glass is broken.

FOR SERVICE TECHNICIAN’S USE ONLY

2

L

BK

VDR

CF Cooling Fan Motor (Magnetron Fan Motor)

TT Turntable Motor

Y: Yellow GY: Gray BU: Blue

Y

4

2

BU

1

CL

Lamp Relay 4902

R BK

CF

BK

BR

TT

BR

Fan TT Relay Relay 4901 4906

9017

P2-5 P2-3 P2-1

BR

BR

P2-6 P2-4 P2-2

BU

P1-3

W: White BR: Brown Y / G: Yellow/Green

R: Red BK: Black

BR

2

BU

4

2

Wire Color - Brown

1

N P1-2

1

Y

P3-1

W

Primary Interlock Switch

MW Fuse Relay 250mA 4903

R

P1, P2, P3, P8, P10, P31, P32, P33, P34, CN701, CN702, CN;703, E701 WIRE TO BOARD CONNECTORS

W

Monitor Interlock Switch

Light Power Supply R

Electronic Control

Inverter Control

CL Halogen Cavity Lamp

W

Cavity Thermostat

P34

Cy

Cy

P33

4

100E

Condition: Door Open. Symbol Notes

VDR

P31

L

Cx

VDR

N

R

L

P1-1 L

BR

2

P3-2 Door

W

MW Inverter

F

R

FA

R

CN703

CN702

CN701

Magnetron No Load Cavity Thermostat

W

Magnetron Thermostat

NFS

P8

BU

1

W

Cx

P32

P10

User Interface Board

BK

Secondary Interlock Switch 1

1

GND G

Line 120V, 60Hz

AC Line Filter

BK

Fuse 20 Amp

E701

WIRING DIAGRAMS Schematic Diagram Y/G

Parts Layout (not to scale)

B

C

D

E

F

G

H

I J K

A

L

R

M

N O P Q A. Primary interlock switch B. Cavity thermostat—opens at 239ºF (115ºC), closes at -31ºF (-35ºC) C. User interface board D. Electronic control E. Fuse holder F. Line fuse (20 amp) G. AC line filter H. Cavity lamp I. L.V. light transformer J. Cooling fan motor

K. Inverter (switch mode power supply) L. Magnetron M. Magnetron thermostat—opens at 293ºF (145ºC), closes at 250ºF (121ºC) N. Monitor interlock switch O. Secondary interlock switch P. No load cavity thermostat—opens at 257ºF (125ºC), closes at 185ºF (85ºC) Q. Turntable motor R. Control panel

3

Primary, Secondary, and Monitor Interlock Switch Checkout Procedure Switch

Check By

Primary Interlock

1. Unplug microwave oven or disconnect power. 2. Disconnect the wires at the Primary Interlock Switch. 3. Check from the common terminal (white/blue wires) to the normally open terminal (yellow/white wires).

Secondary Interlock

Door Open

Door Closed

-

+

-

+

+

-

-

+

+

-

1. Unplug microwave oven or disconnect power. 2. Disconnect the wires at the Secondary Interlock Switch. 3. Check from the common terminal (black/brown wires) to the normally open terminal (blue/red wires). 1. Unplug microwave oven or disconnect power. 2. Disconnect the wires at the Secondary Interlock Switch. 3. Check from the common terminal (black/brown wire) to the normally closed terminal (blue wire). 1. Unplug microwave oven or disconnect power. 2. Disconnect the wires at the Monitor Interlock Switch. 3. Check from the common terminal (blue wire) to the normally open terminal (no wire).

Monitor Interlock

1. Unplug microwave oven or disconnect power. 2. Disconnect the wires at the Monitor Interlock Switch. 3. Check from the common terminal (blue wire) to the normally closed terminal (yellow wire). (+) Continuity (-) No Continuity

NOTE: These diagrams are not intended to show a complete circuit; they represent the position of switches during “DOOR OPEN” or “DOOR CLOSED” (continuity checks only).

Door Closed L

(NC)

Door Open

(NO)

Secondary Interlock Switch

(NO)

N

(NC) (NC)

Monitor Interlock Switch

(NO) Primary Interlock Switch

L

(NC)

(NO)

(NO)

Secondary Interlock Switch

(NC)

Monitor Interlock Switch

(NC)

N (NO)

Primary Interlock Switch

TROUBLESHOOTING Do not continue with the diagnostics of appliance if the household fuse is blown, a circuit breaker is tripped or if there is less than 120-volt power supply at the wall outlet. Complete the following steps before checking microwave oven circuitry: 1. Unplug microwave oven or disconnect power. 2. Check for loose wiring or incorrect wiring within microwave oven.

4

3. All testing must be done with an ohmmeter having a sensitivity of 20,000 ohms per volt DC or greater, and powered by at least a 9-volt battery. 4. All operational checks using microwave energy must be done with the microwave oven loaded with a minimum of 8 oz (250 mL) of water in a microwave safe container.

Microwave oven cooking L1 N Secondary Interlock Switch

Fuse 20 Amp

1

Filter

4

H 2

Primary Interlock Switch

No Load Thermostat

MW Relay

V

1

Cavity Thermostat

1

4

Filter

Magnetron Thermostat

S High Voltage System

Turntable Motor

Turntable Relay

TT

Fuse 250mA

Inverter Control

Light Power Supply

Lamp Relay

Cavity Lamp

Fan Motor Fan Relay CF

Microwave oven plugged in—time of day displayed

Fuse 20 Amp

Secondary Interlock Switch 2 1

BK

BU

4 User Interface Board BR

BK

R P3-2

P1-1 AC Line Filter P32

Cx

Cx

P31

VDR

L

W

2 P34 4

Monitor Interlock Switch 1

Light Power Supply R

BR

BK

MW Relay 4903

Fuse 250mA

P2-4 P2-2

CN701

BR

CN702

E701

TT Inverter Control

Lamp Relay 4902

MW Inverter

P8

CN703 CF

Y

Cavity Thermostat

P2-6

CL R

W

1 1

VDR

R

Cy

N

2

Electronic Control

BU

Cy

1

GND G

BU

P33 L

100E

BK

Line 120V, 60Hz

Door

L

P10

VDR

L

BR

BK

P2-5

P2-3 P2-1

R

F

FA

W

BR

Y/G Magnetron

9017

Fan TT Relay Relay 4901 4906

N P1-3

NFS

P1-2

No Load Cavity W Thermostat

P3-1 Magnetron Thermostat

Primary Interlock Switch

BU

2

W 1 Condition: Door Closed. Microwave oven plugged in - time of day displayed.

R

4

Y W

5

Control Panel Control Panel and Electronic Control Test The built-in microwave oven is provided with a self-diagnostic routine that can be accessed through the control panel keypad.

To initiate this routine: 1. 2. 3. 4.

Unplug microwave oven or disconnect power. Open the microwave oven door. Press and hold STOP. Plug in microwave oven or reconnect power. All LCD segments will be lit to indicate the test mode has been entered. 5. Release the STOP button and close the door.

NOTES: ■ If the STOP button is pressed during this diagnostic routine, you will exit the test mode. ■ When entering the test mode with the function selector set to Off, the cavity light will not turn on. ■ With the door open, pressing any key, turning the function selector or setting dial will set all ouputs to off.

Key Table for Test Mode NOTE: Activate keys and turn dial to check functions according to the table below. The result of all actions will be active until any new action is chosen. All relays are on until next action or until time-out. Selector Position

Key

Display

Off

-

Manual

Defrost

Reheat

6

MW Relay

Cavity Cooling Lamp Fan Turntable Buzzer

All segments On

-

-

-

-

-

Selector in Off position. Close door to continue.

-

----

-

-

-

-

-

Turn setting dial clockwise to continue.

Dial CW

----

-

-

-

-

On

Turn setting dial counterclockwise to continue.

Dial CCW

----

-

-

On

On

-

Food Class

3

-

On

-

-

-

Power

4

-

-

On

-

-

Start

1

-

-

On

-

-

Dial CW

8

-

On

On

On

-

Dial CCW

8

-

On

On

On

-

Food Class

8

-

On

On

On

-

Power

8

-

On

On

On

-

Start

8

-

On

On

On

-

Dial CW

7

-

-

-

-

-

Dial CCW

7

-

-

-

-

-

Food Class

7

-

-

-

-

-

Power

7

-

-

-

-

-

Start

7

-

-

-

-

-

Dial CW

6

-

On

On

On

-

Dial CCW

6

-

On

On

On

-

Food Class

USIF SOFTWARE

-

On

On

On

On

Power

USIF EEPROM -

On

On

On

-

Start

6

On

On

On

-

-

Comment

Selector Position Cook

Dinner Plate

Baked Potatoes

Popcorn

Set Clock

Key

Display

MW Relay

Cavity Cooling Lamp Fan Turntable Buzzer

Dial CW

5

-

-

-

-

-

Dial CCW

5

-

-

-

-

-

Food Class

PWR SOFTWARE

-

-

-

-

-

Power

PWR EEPROM -

-

-

-

-

Start

5

-

-

-

-

-

Dial CW

4

-

-

-

-

-

Dial CCW

4

-

-

-

-

-

Food Class

Ambient temperature ºC

-

-

-

-

Power

4

-

-

-

-

-

Start

4

-

-

-

-

-

Dial CW

3

-

On

On

On

-

Dial CCW

3

-

On

On

On

-

Food Class

3

-

On

On

On

-

Power

3

-

On

On

On

-

Start

3

-

On

On

On

-

Dial CW

2

-

-

-

-

-

Dial CCW

2

-

-

-

-

-

Food Class

2

-

-

-

-

-

Power

2

-

-

-

-

-

Start

2

-

-

-

-

-

Dial CW

1

-

On

On

On

-

Dial CCW

1

-

On

On

On

-

Food Class

1

-

On

On

On

-

Power

1

-

On

On

On

-

Start

1

-

On

On

On

-

Comment

Hardware + Processor

Electronic Control temperature (not used)

Microwave Oven Power Output Test 1. Place 8 oz (250 mL) of lukewarm water in the center of the microwave oven. 2. Operate on HIGH power level for 4 minutes. Water should be hot.

NOTE: If the water takes longer than 4 minutes to heat, this may indicate either the operating voltage is lower than 110 volts or there is a problem with the microwave oven.

Failure Codes Indications NOTE: Many of the problems listed in the chart below may be solved by power cycling: Unplug microwave oven or disconnect power. After 1 minute, plug in microwave oven or reconnect power.

Display

Likely Failure Condition

Recommended Repair Procedure

Steady colon “:”

Power failure

After a power failure, the colon “:” will be steady. Press any key to end this indication. The colon will remain steady when in standby, unless the clock has been set.

7

Display

Likely Failure Condition

Recommended Repair Procedure

Err7

Key error

1. Unplug microwave oven or disconnect power. 2. Check for stuck key (button). The error code should disappear when the key is released. 3. Replace control panel. 4. Replace all parts and panels before operating. 5. Plug in microwave oven or reconnect power. 6. If problem persists, unplug microwave oven or disconnect power. 7. Replace electronic control. 8. Replace all parts and panels before operating. 9. Plug in microwave oven or reconnect power.

Component Tests IMPORTANT: ■ Unplug microwave oven or disconnect power. ■ Remove the lead wires from the related component before conducting any of the following tests. ■ All operational checks using microwave energy must be done with the microwave oven loaded with a minimum of 8 oz (250 mL) of water in a microwave safe container. ■ Conduct a microwave energy test after performing any tests or repairs to the microwave oven.

■ Check that all wire leads are in the correct positions before operating the microwave oven. ■ Grasp wire connectors when removing the wire leads from microwave oven parts. ■ All testing must be done with an ohmmeter having a sensitivity of 20,000 ohms per volt DC or greater, and powered by at least a 9-volt battery.

Components

Test

Magnetron

1. Unplug microwave oven or disconnect power. 2. Remove wire leads. Check that the seal is in good condition. 3. Measure resistance: ■ Filament to terminal: Normal: Less than 1 ohm ■ Filament to chassis: Normal: Infinite

AC Line Filter

1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure resistance: ■ P31 and P32, P33 and P34: Normal: Greater than or equal to 300k ohms ■ P31 and P34, P32 and P33: Normal: 0 ohm; Abnormal: Greater than or equal to 100k ohms

P34 P31

P33

P32

Monitor Fuse

1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure resistance: ■ Normal: Continuity ■ Abnormal: Infinite

L.V. Light Transformer

1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure resistance: ■ Primary winding: 45 ohms (approximate) ■ Secondary winding: 0.6 ohm (approximate)

Cooling Fan Motor

1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure resistance: ■ Normal: 42 ohms (approximate) ■ Abnormal: Infinite

8

Components

Test

Turntable Motor

1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure resistance: ■ Normal: 2,450 ohms (approximate) ■ Abnormal: Infinite

Thermostats

1. Unplug microwave oven or disconnect power. 2. Remove wire leads. 3. Measure continuity: ■ Cavity and Magnetron Thermostats: Normal: Continuity; Abnormal: Infinite ■ No-Load Cavity Thermostat: Normal: Continuity; Abnormal: Infinite

Cavity Thermostat

Magnetron Thermostat

No-Load Cavity Thermostat

Checking Inverters Measure Oven Input Current If more than 0.5A: The MW inverter is probably OK. Check the magnetron. See Magnetron test in “Component Tests.”

15A

If less than 0.5A: Ampères Connect an ammeter (Valhalla Scientific 2101 or equivalent recommended) to measure the input current of microwave oven when the power level is set to Level 10 at the control panel.

There is no input to the MW inverter. Check the following: 1. Unplug microwave oven or disconnect power. 2. No AC voltage supply. Check electronic control and wiring. 3. No control signal. Check electronic control and wiring.

Check the MW Inverter

A

NOTE: Do not try to repair the inverter board, nor try to make any adjustments to the board.

B

Check wiring to MW inverter: 1. Unplug microwave oven or disconnect power. 2. Visually inspect 4 connectors on the MW inverter board, CN701, CN702, CN703, E701, to see whether there are signs of overheating or any signs of failure due to loose wires, bad crimping, etc.

H

G

C F

E

A. CN702 B. Heat sink C. High-voltage output to magnetron D. CN703

D E. E701 F. Control signal in/out G. CN701 H. 120V AC

9

Fiche technique

À conserver

AVERTISSEMENT

Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche. Le non-respect de ces instructions peut causer un décès ou un choc électrique.

PRÉCAUTIONS À PRENDRE AVANT ET PENDANT LES RÉPARATIONS POUR ÉVITER UNE EXPOSITION EXCESSIVE À L'ÉNERGIE DES MICRO-ONDES a. Ne pas faire fonctionner le four lorsque la porte est ouverte. b. Sur chaque four, avant d'alimenter le magnétron ou une autre source de micro-ondes, exécuter les contrôles de sécurité suivants et effectuer les réparations nécessaires : 1. Système d'interverrouillage— fonctionnement 2. Porte—fermeture correcte 3. Joint et surfaces de scellement (formation d’arcs, usure et autres détériorations) 4. Charnières et loquets— détérioration ou mauvais ajustements (desserrage) 5. Indices de détérioration par chute ou d’emploi abusif

W10197623A / 461969469781 10

c. Avant de mettre le four à micro-ondes sous tension pour des opérations de test ou d’inspection dans les compartiments de génération de micro-ondes, contrôler le magnétron, le guide d'ondes/canal de transmission et la cavité —contrôler l'alignement correct, l'intégrité, les connexions. d. Avant de remettre le four à son propriétaire, toute défectuosité ou mauvais ajustement de composant affectant l'interverrouillage, le moniteur, le joint de porte et les systèmes de génération/transmission de micro-ondes, devra être éliminé par réparation/remplacement/ réglage conformément aux procédures décrites dans ce manuel. e. Avant de remettre l'appareil à son propriétaire, on doit effectuer un test de mesure du taux de fuite de micro-ondes, pour vérifier que l'appareil satisfait aux critères des normes CSA. f. Ne pas tenter de faire fonctionner le four si la vitre de la porte est brisée. À L’USAGE DU TECHNICIEN SEULEMENT

N

VDR

CF Moteur - ventilateur de refroidissement (Moteur - ventilateur magnétron)

TT Moteur - plateau rotatif

JA: Jaune GRIS: Gris BU: Bleu

JA

4

2

BL

P2-3

BL: Blanc R: Rouge MAR: Marron N: Noir JA / VE: Jaune / Vert

1

P3-1

Porte

P3-2

Contacteur Interverrouillage Primaire 2 JA 1 4 BL

N P1-2

Fil marron

BU

P1-3

MAR

9017

P2-1

MAR

MAR

P2-2

Relais Relais ventilateur TT 4901 4906

P2-5

MAR N

CF

TT

P2-4

MAR N

P2-6

P1, P2, P3, P8, P10, P31, P32, P33, P34, CN701, CN702, CN703, E701 Connecteurs fils-carte

Relais lampe du four 4902

R

Alimentation éclairage Contacteur R interverrouillage de contrôle CL 1

2

BU

Relais micro-oondes Fusible 4903 250mA

R

Commande d'onduleur

CL Lampe halogéne - cavité du four

BL

Thermostat cavité du four

P34

Cy

P1-1

4

100E

Situation: Porte ouverte Symboles

VDR

P31

L

Cx

Cy

BU

Carte des circuits de commande

L

MAR

2

NFS

P8

1

N

Cx

R

L

P33

P10

Carte interface-utilisateur

N

Contacteur interverrouillage secondaire 1

Magnétron

F

R

FA

R

E701

Onduleur micro-ondes CN703

CN702

CN701

Thermostat de cavité sans charge

BL

Thermostat magnétron

BL

BU

1

BL

VE

P32

VDR

Terre

Phase 120V, 60Hz

L

Filtre sur ligne CA

N

Fusible 20 A

SCHÉMAS DE CÂBLAGE Schéma des circuits JA / VE

11

Répartition des composants (pas à l’échelle)

B

C

D

E

F

G

H

I J K

A

L

R

M

N O P Q A. Contacteur interverrouillage primaire K. Onduleur (alimentation en mode commuté) B. Thermostat—cavité du four—ouvert à 239ºF L. Magnétron (115ºC), fermé à -31ºF (-35ºC) M. Thermostat—magnétron—ouvert à 293ºF C. Carte interface-utilisateur (145ºC), fermé à 250ºF (121ºC) D. Carte des circuits de commande N. Contacteur interverrouillage de contrôle E. Porte-fusible O. Contacteur interverrouillage secondaire F. Fusible (alimentation) (20 A) P. Thermostat de cavité sans charge—ouvert G. Filtre sur ligne CA à 257ºF (125ºC), fermé à 185ºF (85ºC) H. Lampe—cavité du four Q. Moteur—plateau rotatif I. Transformateur éclairage BT R. Tableau de commande J. Moteur—ventilateur de refroidissement

12

Processus de contrôle des contacteurs—primaire, secondaire et contrôle Contacteur

Pour contrôler

Interverrouillage primaire

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Déconnecter les fils du contacteur d’interverrouillage primaire. 3. Vérifier l’alimentation du connecteur commun (connecteurs blanc/bleu) au connecteur normalement ouvert (connecteurs jaune/blanc).

Interverrouillage secondaire

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Déconnecter les fils du contacteur d’interverrouillage secondaire. 3. Vérifier l’alimentation du connecteur commun (connecteurs noir/ marron) au connecteur normalement ouvert (connecteurs bleu/ rouge).

Porte ouverte

Porte fermée

-

+

-

+

+

-

-

+

+

-

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Déconnecter les fils du contacteur d’interverrouillage secondaire. 3. Vérifier l’alimentation du connecteur commun (connecteurs noir/ marron) au connecteur normalement fermée (connecteur bleu). Interverrouillage de 1. Débrancher le four à micro-ondes ou déconnecter la source de contrôle courant électrique. 2. Déconnecter les fils du contacteur d’interverrouillage de contrôle. 3. Vérifier l’alimentation du connecteur commun (connecteur bleu) au connecteur normalement ouvert (pas de connecteur). 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Déconnecter les fils du contacteur d’interverrouillage de contrôle. 3. Vérifier l’alimentation du connecteur commun (connecteur bleu) au connecteur normalement fermée (connecteur jaune). (+) Continuité (-) Circuit ouvert

REMARQUE : Ces schémas ne présentent pas un circuit complet; ils représentent la position des contacteurs pour PORTE OUVERTE ou PORTE FERMÉE (pour contrôle de continuité seulement).

Porte fermée L

(NF)

Porte ouverte

(NO)

Contacteur interverrouillage secondaire

(NO)

(NF) (NF)

Contacteur interverrouillage de contrôle

NEU (NO)

Contacteur interverrouillage primaire

L

(NF)

(NO)

Contacteur interverrouillage secondaire

(NO)

(NF)

Contacteur interverrouillage de contrôle

(NF)

NEU (NO)

Contacteur interverrouillage primaire

DÉPANNAGE Ne pas poursuivre le diagnostic de l'appareil si le fusible est grillé, si un disjoncteur est ouvert, ou si la tension d'alimentation de la prise murale est inférieure à 120 volts. Exécuter les opérations suivantes avant de contrôler les circuits du four à micro-ondes : 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Rechercher des fils du four à micro-ondes mal connectés ou déconnectés.

3. Exécuter tous les contrôles avec un ohmmètre à résistance interne de 20 000 ohms par volt CC ou plus, alimenté par une pile d’au moins 9 volts. 4. Pour tous les contrôles impliquant la génération de microondes, on doit placer à l’intérieur du four au moins 8 oz (250 mL) d’eau dans un récipient compatible avec les micro-ondes.

13

Cuisson aux micro-ondes L1

Contacteur interverrouillage secondaire

Fusible 20A Filtre

1

4

2

Contacteur interverrouillage primaire

Thermostat sans charge

Relais micro-ondes

NEU Thermostat cavité du four

H V

1

4

1

Filtre

Thermostat magnétron

S Circuit haute tension Moteur plateau rotatif

Relais plateau rotatif

TT Fusible 250mA

Commande d'onduleur

Relais - lampe du four

Alimentation éclairage

Lampe cavité du four

Moteur - ventilateur Relais - ventilateur CF

Four à micro-ondes branché—heure affichée

Fusible 20 A

Contacteur interverrouillage secondaire 2 1

N

BU

4 Carte interface-utilisateur MAR N Filtre sur ligne CA

BU

Cx

P2-6 Alimentation éclairage R

P31

VDR

L

BL

2 P34 4

MAR N

Contacteur interverrouillage de contrôle CL 1

MAR

E701

TT

Relais lampe du four 4902

MAR

N

P2-5

P2-3 P2-1

R BL

MAR

BU BL

FA JA / VE

Thermostat de cavité sans charge BL N P1-3

Condition : Porte fermée. Four à micro-ondes branché—heure affichée.

F

R

Magnétron

9017

Relais - Relais ventilateur TT 4901 4906

14

Onduleur micro-ondes CN702

P8

Commande d'onduleur R

Thermostat cavité du four

CN701

CN703 CF

JA

BL

P2-4 P2-2

1

Relais micro-oondes Fusible 4903 250mA 100E

Cx

1 1

Cy

2

Carte des circuits de commande

BU

Cy

N

P3-2 Porte

L

R

Terre VE

P10 P33

L Phase 120V, 60Hz

VDR

N

P32

VDR

L

R

P1-1

NFS

P1-2

P3-1

Contacteur interverrouillage primaire 2 JA 1 4 BL

Thermostat magnétron

Tableau de commande Test du tableau de commande et de la carte des circuits de commande La four à micro-ondes encastré comporte un système d’autodiagnostic commandé par l’intermédiaire du clavier.

Pour exécuter le processus : 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Ouvrir la porte du four à micro-ondes. 3. Appuyer sur la touche STOP. 4. Brancher le four à micro-ondes ou reconnecter la source de courant électrique. Tous les segments LCD seront allumés pour indiquer que le mode test est en cours. 5. Lâcher la touche STOP et fermer la porte.

REMARQUES : ■ Si on appuie sur la touche STOP pendant ce diagnostic, le mode de test est annulé. ■ Lorsque l’on entre au mode de test avec le sélecteur de fonction placé à Off (arrêt), la lampe de la cavité ne s’allume pas. ■ En gardant la porte ouverte, appuyer sur n’importe quelle touche, tourner le sélecteur de fonction ou régler le bouton de réglage entraînera l’arrêt de toutes les sorties.

Tableau des touches pour le mode de test REMARQUE : Activer les touches et tourner un bouton de réglage pour vérifier les fonctions en fonction du tableau cidessous. Le résultat de toutes les actions restera actif jusqu’à ce qu’une nouvelle action soit choisie. Tous les relais restent activés jusqu’à l’exécution de l’action suivante ou jusqu’à l’expiration du délai maximal. Relais - Lampe micro- cavité Ventilateur de la Plateau ondes du four refroidissement rotatif

Position du sélecteur

Touche

Affichage

Off (arrêt)

-

All segments On (Tous les segments marche)

-

-

-

-

-

---

-

-

-

-

-

Dial CW (rotation sens horaire)

---

-

-

-

-

Marche

Tourner le bouton de réglage dans le sens horaire pour continuer.

Dial CCW (rotation sens antihoraire)

---

-

-

Marche

Marche

-

Tourner le bouton de réglage dans le sens antihoraire pour continuer.

Food Class 3 (type d’aliment)

-

Marche

-

-

-

Power (mise sous tension)

4

-

-

Marche

-

-

Start (mise en marche)

1

-

-

Marche

-

-

Dial CW (rotation sens horaire)

8

-

Marche

Marche

Marche

-

Dial CCW (rotation sens antihoraire)

8

-

Marche

Marche

Marche

-

Food Class 8 (type d’aliment)

-

Marche

Marche

Marche

-

Power (mise sous tension)

8

-

Marche

Marche

Marche

-

Start (mise en marche)

8

-

Marche

Marche

Marche

-

Manual (manuel)

Boutonsignal Commentaire Sélecteur à la position fermée. Fermer la porte pour continuer.

15

Affichage

Relais - Lampe micro- cavité Ventilateur de la Plateau ondes du four refroidissement rotatif

Boutonsignal Commentaire

Defrost Dial CW (décongélation) (rotation sens horaire)

7

-

-

-

-

-

Dial CCW (rotation sens antihoraire)

7

-

-

-

-

-

Food Class 7 (type d’aliment)

-

-

-

-

-

Power (mise sous tension)

7

-

-

-

-

-

Start (mise en marche)

7

-

-

-

-

-

Dial CW (rotation sens horaire)

6

-

Marche

Marche

Marche

-

Dial CCW (rotation sens antihoraire)

6

-

Marche

Marche

Marche

-

Food Class USIF (type d’aliment) SOFTWARE (LOGICIEL USIF)

-

Marche

Marche

Marche

Marche

Power (mise sous tension)

USIF EEPROM

-

Marche

Marche

Marche

-

Start (mise en marche)

6

-

Marche

Marche

Marche

-

Cook (cuisson) Dial CW (rotation sens horaire)

5

-

-

-

-

-

Dial CCW (rotation sens antihoraire)

5

-

-

-

-

-

Food Class PWR (type d’aliment) SOFTWARE (LOGICIEL PWR)

-

-

-

-

-

Power (mise sous tension)

PWR EEPROM

-

-

-

-

-

Start (mise en marche)

5

-

-

-

-

-

Position du sélecteur

Reheat (réchauffage)

16

Touche

Quincaillerie + processeur

Touche

Affichage

Relais - Lampe micro- cavité Ventilateur de la Plateau ondes du four refroidissement rotatif

Dial CW (rotation sens horaire)

4

-

-

-

-

-

Dial CCW (rotation sens antihoraire)

4

-

-

-

-

-

Food Class Ambient (type d’aliment) temperature ºC (température ambiante ºC)

-

-

-

-

Power (mise sous tension)

4

-

-

-

-

-

Start (mise en marche)

4

-

-

-

-

-

Dial CW (rotation sens horaire)

3

-

Marche

Marche

Marche

-

Dial CCW (rotation sens antihoraire)

3

-

Marche

Marche

Marche

-

Food Class 3 (type d’aliment)

-

Marche

Marche

Marche

-

Power (mise sous tension)

3

-

Marche

Marche

Marche

-

Start (mise en marche)

3

-

Marche

Marche

Marche

-

Popcorn (maïs Dial CW éclaté) (rotation sens horaire)

2

-

-

-

-

-

Dial CCW (rotation sens antihoraire)

2

-

-

-

-

-

Food Class 2 (type d’aliment)

-

-

-

-

-

Power (mise sous tension)

2

-

-

-

-

-

Start (mise en marche)

2

-

-

-

-

-

Dial CW (rotation sens horaire)

1

-

Marche

Marche

Marche

-

Dial CCW (rotation sens antihoraire)

1

-

Marche

Marche

Marche

-

Food Class 1 (type d’aliment)

-

Marche

Marche

Marche

-

Power (mise sous tension)

1

-

Marche

Marche

Marche

-

Start (mise en marche)

1

-

Marche

Marche

Marche

-

Position du sélecteur Dinner Plate (assiettée)

Baked Potatoes (pommes de terre au four)

Set Clock (horloge)

Boutonsignal Commentaire

Commande électronique— température (pas utilisé)

17

Test de la puissance du four à micro-ondes 1. Placer un récipient d'eau tiède (8 oz [250 mL]) au centre du four. 2. Faire fonctionner le four au niveau de puissance maximum (HIGH) pendant 4 minutes. L'eau devrait être chaude.

REMARQUE : Si plus de 4 minutes sont nécessaires pour chauffer l'eau, il se peut que le voltage soit inférieur à 110 volts ou qu'il y ait un problème avec le four à microondes.

Identification des codes de défaillance REMARQUE : De nombreux problèmes reportés dans le tableau ci-dessous peuvent être résolus en arrêtant et relançant l'alimentation électrique : débrancher le four à micro-ondes ou déconnecter la source de courant électrique. Après une minute, brancher le four à micro-ondes ou reconnecter la source de courant électrique.

Affichage

Défaillance probable

Méthode de réparation recommandée

Clignotement “:”

Panne d’électricité

Après une panne d’électricité, on observe le clignotement du “:”. Appuyer sur une touche quelconque pour mettre fin au clignotement. L’affichage devient stable (mode d’attente).

Err7

Erreur touche

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Vérifier qu’il n’y a pas de touche bloquée (bouton). Le code d’erreur doit disparaître lorsque l’on relâche cette touche. 3. Remplacer le tableau de commande tactile. 4. Replacer pièces et panneaux avant de faire la remise en marche. 5. Brancher le four à micro-ondes ou reconnecter la source de courant électrique. 6. Si le problème persiste, débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 7. Remplacer la carte des circuits de commande. 8. Replacer pièces et panneaux avant de faire la remise en marche. 9. Brancher le four à micro-ondes ou reconnecter la source de courant électrique.

Tests des composants IMPORTANT : ■ Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. ■ Avant d’exécuter les tests suivants, débrancher les fils de connexion du composant. ■ Pour tous les contrôles impliquant la génération de micro-ondes, on doit placer à l’intérieur du four au moins 8 oz (250 mL) d’eau dans un récipient compatible avec les micro-ondes. ■ Après tout test ou réparation du four à micro-ondes, exécuter un test de contrôle de l’énergie émise par les micro-ondes.

■ Avant de faire fonctionner le four à micro-ondes, vérifier que tous les fils du câblage sont à la position correcte. ■ Pour débrancher les conducteurs des composants du four à micro-ondes, saisir chaque connecteur. ■ Exécuter tous les contrôles avec un ohmmètre à résistance interne de 20 000 ohms par volt CC ou plus, alimenté par une pile d’au moins 9 volts.

Composants

Test/Résultats

Magnétron

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Débrancher les conducteurs. Vérifier que le joint est en bon état. 3. Mesurer la résistance : ■ Bobinage filament : Normal : Moins de 1 ohm ■ Bobinage filament—châssis : Normal : résistance infinie

18

Composants

Test/Résultats

Filtre sur ligne CA

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Débrancher les conducteurs. 3. Mesurer la résistance : ■ P31 et P32, P33 et P34 : Normal : supérieur ou égal à 300k ohms; ■ P31 et P34, P32 et P33 : Normal : 0 ohm; Anormal : supérieur ou égal à 100k ohms

P34

P33

P31

P32

Fusible

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Débrancher les conducteurs. 3. Mesurer la résistance : ■ Normal : continuité; ■ Anormal : résistance infinie

Transformateur d’éclairage BT

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Débrancher les conducteurs. 3. Mesurer la résistance : ■ Sens direct : 45 ohms (environ) ■ Sens inverse : 0,6 ohm (environ)

Moteur—ventilateur de refroidissement

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Débrancher les conducteurs. 3. Mesurer la résistance : ■ Normal : 42 ohms (environ) ■ Anormal : résistance infinie

Moteur—Plateau rotatif 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Débrancher les conducteurs. 3. Mesurer la résistance : ■ Normal : 2 450 ohms (environ) ■ Anormal : résistance infinie 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Débrancher les conducteurs. 3. Mesurer la continuité : ■ Thermostats—cavité et magnétron : Normal : continuité; Anormal : résistance infinie Thermostats ■ Thermostat—cavité sans charge : Normal : continuité; Anormal : résistance infinie cavité du four

Thermostats

Thermostat magnétron

Thermostat cavité sans charge

19

Contrôle des onduleurs Mesure du courant à l’entrée du four Si on mesure plus de 0,5 A : L’onduleur de micro-ondes est probablement correctement allimenté. Contrôler le magnétron. Voir le test du magnétron à la section “Tests des composants”.

15A

Si on mesure moins de 0,5 A :

Ampères Connecter un ampèremètre (Valhalla Scientific 2101 recommandé ou modèle équivalent) pour mesurer l’intensité du courant d’entrée du four à micro-ondes lorsque le niveau de puissance est réglé au Niveau 10 sur le tableau de commande.

L’onduleur de micro-ondes n’est pas alimenté. Vérifier ce qui suit : 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Aucune alimentation en tension alternative. Contrôler la carte des circuits électroniques et les branchements. 3. Aucun signal de contrôle. Contrôler la carte des circuits électroniques et les branchements.

Contrôle de l’onduleur de micro-ondes

A

REMARQUE : Ne pas tenter de réparer un circuit onduleur ni d’effectuer un réglage sur le circuit.

B

Contrôle des branchements de l’onduleur de microondes : 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique. 2. Inspecter visuellement les 4 connecteurs sur le circuit onduleur de micro-ondes (CN701, CN702, CN703, E701) pour détecter les signes de surchauffe ou toute autre anomalie due à des fils mal branchés, un mauvais sertissage, etc.

H

G

C F

E

A. CN702 B. Plaque de refroidissement C. Sortie haute tension vers le magnétron D. CN703

D E. E701 F. Signal de contrôle entrée/sortie G. CN701 H. 120V CA

W10197623A / 461969469781

6/08 FOR SERVICE TECHNICIAN’S USE ONLY À L’USAGE DU TECHNICIEN SEULEMENT