Sans titre

ATA Version: 2. SATA Version: ... 0x0033 100 100 010 Prédéfaillance. Toujours Never 45056. 9 Heures sous tension. 0x0032 100 100 001 Vieillesse. Toujours ...
24KB taille 3 téléchargements 522 vues
location: /dev/disk0 partition count: 1 partitions: SSD, SMART Support: Supported Last SMART Error: *not set* Model Family: Crucial/Micron RealSSD m4/C400/P400 Model: M4-CT512M4SSD2 Serial Number: 000000001243091A1C28 Firmware Version: 070H Capacity: 512 GB ATA Version: 2 SATA Version: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Rotation Rate: Solid State Device Health: Failing Overall Health: PASSED Offline Data Status: 80 Self Test Status: 121 Offline Data Collection Time: 2380 Data Collection Capabilities: 7B SMART Capabilities: 3 Error Logging Capabilities: 1 Short Self Test Time: 2 Long Self Test Time: 39 Conveyance Self Test Time: 3 Attribute Log Revision: 16 Attribute Count: 23 Attributes: ID# ATTRIBUTE NAME FLAG 1 Taux d'erreur de lecture brute Toujours Never 8968 5 Nombre de secteurs réalloué Toujours Never 45056 9 Heures sous tension Toujours Never 346 12 Nombre de Power Cycle Toujours Never 2311 170 Nombre de blocs défaillants grandissants Toujours Never 75 171 Nombre d'échecs du programme Toujours Never 0 172 Nombre d'échecs d'effacement Toujours Never 1 173 Wear_Leveling_Count Toujours Never 48 174 Nombre de pertes de courant inattentendues Toujours Never 82 181 Accès aligné non -4K Toujours Never 170 183 Réduction de l'interface SATA Toujours Never 0 184 Erreurs de bout en bout Toujours Never 0 187 Erreurs incorrigibles signalées Toujours Never 10816 188 Commande expirée Toujours Never 0 189 Factory Bad Block Count Toujours Never 161 194 Température Celsius Toujours Never 0 195 Matériel ECC récupéré Toujours Never 3605433 196 Nombre événement réaffecté Toujours Never 75 197 Nombre de secteurs courants en attente Toujours Never 0 198 Nombre de secteurs incorrigibles hors ligne Hors ligne Never 0 199 Nombre d'erreurs CRC UDMA Toujours Never 0 202 Pourcentage de vie nominale utilisé Hors ligne Never 1 206 Taux d'erreurs d'écriture

VALUE

WORST

THRESH TYPE

UPDATED 0x002F

FAILED 100

RAW VALUE 100 050

Prédéfaillance

0x0033

100

100

010

Prédéfaillance

0x0032

100

100

001

Vieillesse

0x0032

100

100

001

Vieillesse

0x0033

100

100

010

Prédéfaillance

0x0032

100

100

001

Vieillesse

0x0032

100

100

001

Vieillesse

0x0033

099

099

010

Prédéfaillance

0x0032

100

100

001

Vieillesse

0x0022

100

100

001

Vieillesse

0x0032

100

100

001

Vieillesse

0x0033

100

100

050

Prédéfaillance

0x0032

100

100

001

Vieillesse

0x0032

100

100

001

Vieillesse

0x000E

100

100

001

Vieillesse

0x0022

100

100

000

Vieillesse

0x003A

100

100

001

Vieillesse

0x0032

100

100

001

Vieillesse

0x0032

100

100

001

Vieillesse

0x0030

100

100

001

Vieillesse

0x0032

100

100

001

Vieillesse

0x0018

099

099

001

Vieillesse

0x000E

100

100

001

Vieillesse

Toujours Never 0 Error Log Version: 1 Error Count: 0 Error Log: Error 0 occured at disk power-on lifetime: 337 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -40 51 38 B0 F2 0B E0 Error: Erreur incorrigible with 56 sectors at LBA = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 2F 00 01 10 00 00 E0 00 14d+01:49:00.000 READ LOG EXT Error -1 occured at disk power-on lifetime: 337 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -40 51 38 B0 F2 0B E0 Error: Erreur incorrigible with 56 sectors at LBA = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 2F 00 01 10 00 00 E0 00 14d+01:49:00.000 READ LOG EXT 60 00 40 A8 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED Error -2 occured at disk power-on lifetime: 337 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -40 51 38 B0 F2 0B E0 Error: Erreur incorrigible with 56 sectors at LBA = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 2F 00 01 10 00 00 E0 00 14d+01:49:00.000 READ LOG EXT 60 00 40 A8 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED 60 00 40 68 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED Error -3 occured at disk power-on lifetime: 337 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -40 51 38 B0 F2 0B E0 Error: Erreur incorrigible with 56 sectors at LBA = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------25 00 40 A8 F2 0B E0 00 14d+01:49:00.000 READ DMA EXT 2F 00 01 10 00 00 E0 00 14d+01:49:00.000 READ LOG EXT 60 00 40 A8 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED 60 00 40 68 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED 60 00 40 28 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED Error -4 occured at disk power-on lifetime: 337 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- --

00 50 00 B0 F2 0B 40 Error: Inconnu Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------60 00 40 A8 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED 60 00 40 68 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED 60 00 40 28 F2 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED 60 00 40 E8 F1 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED 60 00 40 A8 F1 0B 40 00 14d+01:49:00.000 READ FPDMA QUEUED Self Test Log Revision: 1 Self Test Log Count: 2 Self Test Log: Num Test_Description # 1 Extended offline # 2 Short offline

Status Remaining LifeTime(hours) LBA_of_first_error Completed: read failure 90% 347 62271760 Completed: read failure 70% 347 988514448

--------------------------