EEDEN07-720
technical data
Altherma
ERYQ005-007AC EKHBH007AC / EKHBX007AC EKSWW150-300
Altherma ERYQ005-007AC EKHBH007AC / EKHBX007AC EKSWW150-300
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
“The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V..”
Naamloze Vennootschap Zandvoordestraat 300 B-8400 Ostend, Belgium www.daikin.eu BTW: BE 0412 120 336 RPR Oostende
EEDEN0 7 - 7 2 0
EEDEN07-720 - 04/2007 Printed in Belgium by Goekint Graphics Copyright © Daikin
Daikin units comply with the European regulations that guarantee the safety of the product.
EEDEN07-720
technical data Altherma
ERYQ005-007AC EKHBH007AC / EKHBX007AC EKSWW150-300
• Chillers • R-410A • ALTHERMA
erA el0 hl1 t4i l-h RAC
Heating only
Heat pump 4
• Altherma • Chillers
• Outdoor units • R-410A • ERYQ
TABLE OF CONTENTS ERYQ
1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Nominal Capacity and Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heating/Cooling capacity tables
4
7 7 9
10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 11 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 12
5
Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 8
14 15
Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
• Altherma • Outdoor units
5
• Outdoor units • R-410A • ERYQ
1 i n u a r m o rA o e0 dh1Q t4Y uRl- EA•OR
1
•
Features Cost effective alternative to a fossil fuel boiler
•
Easy to install
Low energy bills and low CO2 emissions
•
Total solution for year round comfort
1
6
• Altherma • Outdoor units
• Outdoor units • R-410A • ERYQ
2
Specifications
2-1 NOMINAL CAPACITY AND NOMINAL INPUT Indoor Units Condition 1
Heating capacity
ERYQ006AC (+ EKHBH)
ERYQ007AC (+ EKHBH)
ERYQ005AC (+ EKHBX)
ERYQ006AC (+ EKHBX)
ERYQ007AC (+ EKHBX)
EKHBH007AC
EKHBH007AC
EKHBH007AC
EKHBX007AC
EKHBX007AC
EKHBX007AC
4.36
4.36
4.36
4.36
4.36
4.36
Minimum
kW
Nominal
kW
5.75
6.84
8.43
5.75
6.84
8.43
Maximum kW
7.45
8.79
9.58
7.45
8.79
9.58
Cooling capacity
Minimum
kW
-
-
-
4.82
4.82
4.82
Nominal
kW
-
-
-
7.20
8.16
8.37
-
-
-
7.20
8.50
8.91
Heating PI
Nominal
kW
1.26
1.58
2.08
1.26
1.58
2.08
Cooling PI
Nominal
kW
-
-
-
2.27
2.78
2.97
COP
Nominal
-
4.56
4.34
4.05
4.56
4.34
4.05
Maximum kW
Condition 2
ERYQ005AC (+ EKHBH)
EER
Nominal
-
Heating
Minimum
kW
Nominal
kW
5.03
6.10
7.64
5.03
6.10
7.64
Maximum kW
6.68
7.98
8.76
6.68
7.98
8.76
Cooling
-
-
-
3.17
2.94
2.82
3.87
3.87
3.87
3.87
3.87
3.87
Minimum
kW
-
-
-
3.67
3.67
3.67
Nominal
kW
-
-
-
5.12
5.86
6.08
Maximum kW
-
-
-
5.12
6.13
7.10 2.54
Heating PI
Nominal
kW
1.58
1.95
2.54
1.58
1.95
Cooling PI
Nominal
kW
-
-
-
2.16
2.59
2.75
COP
Nominal
-
3.18
3.13
3.00
3.18
3.13
3.00
EER
Nominal
-
-
-
-
2.37
2.26
2.21
Notes
1 2
Condition 1: heating Ta DB/WB 7°C/6°C - LWC 35°C ( DT = 5°C ) - cooling Ta 35°C - LWE 7°C Condition 2: heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) - cooling Ta 35°C - LWE 18°C ( DT = 5°C )
2-2 TECHNICAL SPECIFICATIONS Casing Dimensions
Packing
ERYQ006AC (+ EKHBH)
ERYQ007AC (+ EKHBH)
ERYQ005AC (+ EKHBX)
Colour
Ivory white
Material
Polyester painted galvanised steel
Unit
Packing
Weight
ERYQ005AC (+ EKHBH)
Height
mm
735
Width
mm
825
Depth
mm
300
Height
mm
797
Width
mm
960
Depth
mm
390
Unit
kg
56
Packed Unit
kg
61
Material
ERYQ006AC (+ EKHBX)
ERYQ007AC (+ EKHBX)
EPS Carton
Weight Heat Exchanger
Specifications
Length
kg
5
mm
845
mm
1.8
Nr of Rows Fin Pitch
2
Nr of Stages Tube type Fin
Type
WF fin
Treatment Fan
Anti-corrosion treatment (PE)
Type
Propeller
Quantity
1
Discharge direction Motor
Horizontal
Quantity Output
Compressor
1 W
Quantity Motor
32 Hi-Xa(8)
53 1
Model
2YC63BXD#C
Type Motor Output
Hermetically sealed swing compressor W
• Altherma • Outdoor units
1920
7
• Outdoor units • R-410A • ERYQ
2
1 2
Specifications
2-2 TECHNICAL SPECIFICATIONS Operation Range (1)
Heating Cooling Sanitary water
Sound Level (nominal)
Heating
Min
°CDB
-
10
Max
°CDB
-
43
25
Min
°CDB
-20
Max
°CDB
43
Sound Power
dBA
Sound Power
dBA
60
60
61
60
60
61
48
48
49
48
48
49
-
-
-
62
62
63
-
-
-
48
48
50
R-410A kg
1.7 Expansion valve(electronic type)
Nr of Circuits
1
Type
FVC50K
Charged Volume
l
Flare connection mm
6.35
Type
Flare connection
Diameter (OD) Drain
0.75
Type Diameter (OD)
Gas
mm
15,9
Quantity
1
Type
Piping Length
Socket
Diameter (OD)
mm
Minimum
m
3
Maximum m
30
Additional Refrigerant Charge Installation height difference
ERYQ007AC (+ EKHBX)
-20
Type
Liquid (OD)
ERYQ006AC (+ EKHBX)
°CWB
Control
Piping connections
ERYQ005AC (+ EKHBX)
°CWB
Charge
Refrigerant Oil
ERYQ007AC (+ EKHBH)
Min
Sound dBA Pressure (2) Refrigerant
ERYQ006AC (+ EKHBH)
Max
Sound dBA Pressure (2) Cooling
ERYQ005AC (+ EKHBH)
18
kg/m
0.02 IF > 10m
Maximum m
Max. internunit level difference
15 m
20
Defrost Method
Reverse cycle
Defrost Control
Sensor for outdoor heat exchanger temperature
Capacity Control Method
Inverter controlled
Standard Accessories
Installation manual
Item Quantity
1
Item
Drain plug
Quantity
1
Notes
See operation range drawing The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
8
• Altherma • Outdoor units
• Outdoor units • R-410A • ERYQ
2
Specifications
2-3 ELECTRICAL SPECIFICATIONS Power Supply
ERYQ006AC (+ EKHBH)
ERYQ007AC (+ EKHBH)
ERYQ005AC (+ EKHBX)
ERYQ006AC (+ EKHBX)
ERYQ007AC (+ EKHBX)
Name
V1
1
Phase
1~
2
Frequency Voltage Voltage range
Minimum
Hz
50
V
220-240
V
-10%
Maximum V
+10%
Starting Current
Heating
A
11
Cooling
A
11
Maximum running Current
Heating
A
18
Cooling
A
16.25
A
20
Recomended fuses Wiring connections
ERYQ005AC (+ EKHBH)
For Power Supply
Quantity
For connection Quantity with indoor Remark
• Altherma • Outdoor units
3 4 Included earth wiring
9
• Outdoor units • R-410A • ERYQ
3
Capacity tables
3-1
Heating/Cooling capacity tables
HEATING (Peak values)
1
Model
3 005
006
007
LWC Tamb -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7
30 HC 3.93 4.65 5.14 6.06 6.89 8.03 4.87 5.67 6.21 7.23 8.14 9.40 5.42 6.27 6.84 7.92 8.9 10.2
35 PI 1.48 1.52 1.54 1.57 1.57 1.57 1.82 1.88 1.91 1.95 1.97 1.98 2.06 2.13 2.17 2.22 2.26 2.28
HC 3.67 4.32 4.77 5.62 6.38 7.45 4.62 5.34 5.83 6.77 7.61 8.79 5.16 5.93 6.46 7.45 8.35 9.58
40 PI 1.59 1.65 1.68 1.72 1.74 1.75 1.94 2.02 2.07 2.13 2.16 2.19 2.19 2.29 2.34 2.41 2.46 2.51
HC 3.47 4.07 4.49 5.28 6.00 7.00 4.43 5.09 5.55 6.42 7.21 8.32 4.97 5.68 6.17 7.10 7.93 9.10
45 PI 1.71 1.79 1.83 1.88 1.91 1.94 2.08 2.18 2.24 2.32 2.37 2.42 2.34 2.46 2.53 2.62 2.69 2.76
HC 3.33 3.89 4.28 5.03 5.72 6.68 4.30 4.92 5.35 6.17 6.92 7.98 4.86 5.51 5.97 6.85 7.65 8.76
50 PI 1.84 1.94 1.99 2.06 2.11 2.15 2.23 2.36 2.42 2.52 2.59 2.66 2.51 2.65 2.73 2.85 2.93 3.02
HC 3.25 3.78 4.15 4.87 5.53 6.47 4.24 4.82 5.23 6.02 6.74 7.78 4.80 5.42 5.86 6.70 7.47 8.56
PI 1.99 2.10 2.16 2.25 2.31 2.37 2.40 2.55 2.63 2.75 2.83 2.92 2.70 2.86 2.95 3.10 3.20 3.31
HEATING (integrated values*)
Model
005
006
007
LWC Tamb -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7
30 HC 3.50 4.14 4.52 5.27 5.92 8.03 4.34 5.04 5.46 6.29 7.00 9.40 4.82 5.58 6.02 6.89 7.6 10.2
Tamb (°C) LWE (°C) 7 11 13 16 20 7 11 13 16 20 7 11 13 16 20
CC 6.01 6.81 7.23 7.88 8.80 7.15 8.09 8.57 9.33 10.4 8.24 9.26 9.79 10.6 11.7
35 PI 1.40 1.45 1.45 1.46 1.45 1.57 1.73 1.79 1.80 1.81 1.81 1.98 1.96 2.03 2.04 2.07 2.08 2.28
HC 3.27 3.85 4.20 4.89 5.49 7.45 4.11 4.75 5.13 5.89 6.55 8.79 4.59 5.28 5.69 6.48 7.18 9.58
PI 1.56 1.57 1.57 1.56 1.55 2.05 2.09 2.11 2.13 2.16 2.43 2.49 2.52 2.57 2.63
CC 5.73 6.50 6.90 7.54 8.42 6.84 7.73 8.20 8.92 9.9 7.90 8.87 9.38 10.17 11.3
40 PI 1.51 1.56 1.58 1.60 1.60 1.75 1.85 1.92 1.94 1.98 1.99 2.19 2.08 2.17 2.20 2.25 2.27 2.51
HC 3.09 3.62 3.95 4.59 5.16 7.00 3.94 4.53 4.88 5.59 6.20 8.32 4.43 5.06 5.43 6.17 6.82 9.10
PI 1.75 1.77 1.78 1.78 1.79 2.28 2.34 2.36 2.40 2.44 2.68 2.76 2.80 2.86 2.94
CC 5.43 6.17 6.56 7.17 8.03 6.50 7.34 7.79 8.49 9.48 7.52 8.45 8.93 9.69 10.75
45 PI 1.62 1.70 1.72 1.75 1.76 1.94 1.98 2.07 2.10 2.15 2.18 2.42 2.23 2.34 2.37 2.44 2.47 2.76
HC 2.97 3.46 3.77 4.38 4.92 6.68 3.83 4.38 4.71 5.37 5.96 7.98 4.32 4.91 5.26 5.96 6.58 8.76
PI 1.95 1.98 2.00 2.01 2.03 2.52 2.59 2.63 2.68 2.73 2.94 3.05 3.10 3.17 3.26
CC 5.12 5.83 6.20 6.79 7.63 6.13 6.94 7.36 8.03 8.99 7.10 7.79 8.14 8.68 9.39
50 PI 1.75 1.84 1.87 1.92 1.94 2.15 2.12 2.24 2.28 2.35 2.38 2.66 2.39 2.52 2.57 2.65 2.70 3.02
HC 2.89 3.36 3.65 4.24 4.76 6.47 3.77 4.29 4.60 5.23 5.80 7.78 4.27 4.82 5.15 5.83 6.43 8.56
PI 2.16 2.21 2.23 2.26 2.29 2.77 2.87 2.91 2.97 3.04 3.23 3.31 3.36 3.41 3.48
CC 4.80 5.30 5.56 5.95 6.48 5.35 5.84 6.09 6.46 6.96 5.68 6.12 6.34 6.67 7.09
PI 1.89 2.00 2.03 2.10 2.13 2.37 2.28 2.42 2.47 2.56 2.61 2.92 2.56 2.72 2.78 2.88 2.94 3.31
* The integrated heating capacity and power input, is the average heating capacity and power input during 1 cycle. (from end of defrost till end of the next defrost).
COOLING
Model
005
006
007
20
25
30
35
SYMBOLS HC CC PI LWE LWC Tamb
10
40
43 PI 2.39 2.32 2.28 2.22 2.13 2.68 2.62 2.59 2.53 2.44 2.86 2.80 2.77 2.71 2.61
CC 4.59 4.98 5.18 5.46 5.82 4.89 5.21 5.36 5.57 5.82 4.87 5.18 5.33 5.55 5.80
PI 2.53 2.38 2.30 2.18 1.99 2.59 2.43 2.34 2.20 1.99 2.59 2.43 2.35 2.20 1.99
3TW57552-1
NOTES
: Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Power input (kW) : Leaving Water Evaporator temperature (°C) : Leaving Water Condensor temperature (°C) : Ambient temperature (°C) RH=85%
• Altherma • Outdoor units
1
Heating capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 3∼8°C
2
Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 3∼8°C
3
Power input Power input is total input according to Eurovent rating standard 6/C/003-2006
• Outdoor units • R-410A • ERYQ
4
Dimensional drawing & centre of gravity
4-1
Dimensional drawing unit (mm)
ERYQ Drain outlet (I.D. J 15.9 hose for connection)
Minimum space for air passage
Wall height on air outlet side = less than 1200
1 4
In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M10)
Name plate Wiring inlet
Brand name label
Outdoor air thermistor
Terminal strip with earth terminal
Liquid stop valve (J6.4 CuT) Service port
Gas stop valve (J15.9 CuT)
3D051658C
• Altherma • Outdoor units
11
• Outdoor units • R-410A • ERYQ
1
4
Dimensional drawing & centre of gravity
4-2
Centre of gravity
ERYQ
4
The position of foundation bolt 4D042258H
12
• Altherma • Outdoor units
• Outdoor units • R-410A • ERYQ
5
Piping diagram
ERYQ-AC
1
Outdoor unit Heat exchanger
5
Outdoor air temperature thermistor
Capillary tube 1
Capillary tube 2 Capillary tube 3
Heat exchanger thermistor
Muffler with filter
Refrigerant flow Cooling Heating
Capillary tube 4
Filter Motor operated valve
Propeller fan
Filter Four way valve on : heating
Muffler with filter
Field piping
Muffler Liquid stop valve
Muffler Field piping Discharge pipe thermistor
Compressor
Accumulator
Gas stop valve with service port
3D052750B
• Altherma • Outdoor units
13
• Outdoor units • R-410A • ERYQ
1
6
Wiring diagram
6-1
Wiring diagram
ERYQ-AC
6 Power supply
To indoor unit
Sheet metal
Indoor
g Field wiring
(outdoor) (discharge) (Condenser) Outdoor Z1C∼Z7C X1M, X2M Y1E V2, V3, V5, V9, V100 SA2 FU1, FU2, FU3: AC1, AC2 U, V, W, X11A, X12A E1, E2 HR1, HR2
14
: Ferrite core : Terminal strip : Electronic expansion valve coil : Varistor : Surge arrester : Fuse
: Connector
MRM10, MRM20 MRC/W R1T∼R3T S2∼S102 LEDA L N SW1 SW4 M1C M1F L1R
: Magnetic relay : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch SW (SW1) : Local setting SW (SW4) : Compressor motors : Fan motor : Reactor
• Altherma • Outdoor units
Q1L PM1 PCB1,2 Y1R Sheet metal
: Overload protector : Power module : Printed circuit board : Reversing solenoide valve coil : Terminal strip fixed plate
3D052296C
• Outdoor units • R-410A • ERYQ
6
Wiring diagram
6-2
External connection diagram Standard parts
1
Power supply Outdoor unit 3 core
Unit power supply: 230V + earth
For more details please check unit wiring diagram
X1M:L-N-Earth
6
Backup heater power supply (3/6/9kW): 400V or 230V + earth Optional power supply X2M:1-2-3-Earth Booster heater power supply (3kW): 400V or 230V + earth 4 core
3 or4 core
3 core
Optional parts
Field supply X1M:9-10-11-Earth
Sanitary tank 2 way valve
2 core Q3L - Q1T Clixon Thermostat 2 way valve
Only for EKSWWU*V3 Power supply booster heater
5 core
230V or400V Q2L - Clixon booster heater
NO valve: NC valve:
2 core
Thermistor cable Note: min. distance to power cable = 3cm
Room thermostat A3P (optional)
2 core
2 core
R5T - Thermistor water temperature
Signal
4 core
X1M:7-8-Earth
2 way valve M2S (EKHBX Units) for cooling mode
3 way valve M3S (when EKSWW is installed) selection sanitary-floorheating
Indoor unit User interface
3TW56719-6A
• Altherma • Outdoor units
15
• Outdoor units • R-410A • ERYQ
7-1
Sound pressure spectrum
ERYQ005ACV3 Heating
ERYQ006ACV3 Heating Sound pressure level (dB)
7
Sound data
Sound pressure level (dB)
1
7
3TW57557-2
Octave band center frequency (Hz)
3TW57557-2
NOTES 1 2 3 4
Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
1
Coil Microphone
2 3 4
Location of microphone
Octave band center frequency (Hz)
3TW57557-1
16
Microphone
Location of microphone
Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Octave band center frequency (Hz)
NOTES
NOTES
3 4
Coil
Sound pressure level (dB)
Sound pressure level (dB)
3TW57557-2
2
Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
ERYQ005ACV3 Cooling
ERYQ007ACV3 Heating
1
Octave band center frequency (Hz)
NOTES
1 Coil Microphone
2 3 4
Location of microphone
• Altherma • Outdoor units
Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Coil Microphone
Location of microphone
• Outdoor units • R-410A • ERYQ
7
Sound data
7-1
Sound pressure spectrum ERYQ007ACV3 Cooling
3TW57557-1
Octave band center frequency (Hz)
2 3 4
Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
7
3TW57557-1
NOTES 1
1
Sound pressure level (dB)
Sound pressure level (dB)
ERYQ006ACV3 Cooling
Octave band center frequency (Hz)
NOTES 1 Coil Microphone
2 3 4
Location of microphone
• Altherma • Outdoor units
Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Coil Microphone
Location of microphone
17
• Outdoor units • R-410A • ERYQ
8
Operation range
1
Outdoor temp. (°CDB)
8
Heating mode
: Units with optional back up heater
Leaving condenser water temperature (°C)
Cooling mode
Outdoor temp. (°CDB)
Leaving evaporator water temperature (°C)
Outdoor temp. (°CDB)
Sanitary mode
: Booster heater operation only
: Units with optional back up heater or booster heater operation only
Water temperature sanitary tank (°C)
4TW57553-1A
18
• Altherma • Outdoor units
• Indoor units • R-410A • EKHBH / EKHBX
TABLE OF CONTENTS EKHBH / EKHBX
1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 22
3
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24
4
Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 25 Dimensional drawing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5
Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
27 29
Hydraulic performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Static pressure drop unit
• Altherma • Indoor units
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
19
• Indoor units • R-410A • EKHBH / EKHBX
1 H t K i E n u a/ m r rA Ho e0 Bo h1 Hd t4 nKl- E•IAR •
Features Cost effective alternative to a fossil fuel boiler
•
Easy to install
Low energy bills and low CO2 emissions
•
Total solution for year round comfort
2 1
20
• Altherma • Indoor units
• Indoor units • R-410A • EKHBH / EKHBX
2 2-1
Specifications TECHNICAL SPECIFICATIONS
Outdoor units Nominal input (Indoor only) Casing Dimensions
Packing
EKHBH007AC + ERYQ007AC
EKHBX007AC + ERYQ005AC
EKHBX007AC + ERYQ006AC
EKHBX007AC + ERYQ007AC
ERYQ005ACV3
ERYQ006ACV3
ERYQ007ACV3
ERYQ005ACV3
ERYQ006ACV3
ERYQ007ACV3
W
230
Colour
RAL9010 Epoxy polyester painted galvanised steel
Packing
mm
1225
mm
660
Depth
mm
Height
mm
895
936
Width
mm
487
487
Depth
461
595
mm
361
kg
55
65
Gross Weight
kg
65
75
Material
Pump
kg
EPS
EPS
Wood
Wood
Carton
Carton
PS (straps)
PS (straps)
10
10
Type
Water cooled
Nr. of speed Heating
kPa
Cooling
kPa
3 46.5
Water side Heat exchanger
Water flow rate Nom.
40.1
Water filter
46.5
40.1
29.0
49.9
45.9
44.7
130
130
Type
Brazed plate
Qty
1
Water volume
l
Water flow rate Min.
l/min
Heating
l/min
Cooling
l/min
0.67 12 16.5
19.6
Volume
l
Max. water pressure
bar
Pre pressure
bar
Diameter perforations
mm
16.5
19.6
24.1
14.7
16.8
17.4
Polyurethane foam 10 3 1 1
Material Piping connections diameter
24.1
-
Insulation material Expansion vessel
29.0
-
Power input
Brass inch
Piping
inch
Safety valve
bar
1"MBSP 1"MBSP 3
Manometer
Yes
Drain valve / Fill valve
Yes
Shut off valve
Yes
Air purge valve
Yes
Refrigerant Circuit
Gas side diameter
Sound Level Operation range
Waterside
Notes
2
Height
Machine weight
Nominal ESP unit
Water circuit
2
Width
Weight Main components
EKHBH007AC + ERYQ006AC
Material
Unit
Weight
EKHBH007AC + ERYQ005AC
mm
15.9
Liquid side diameter
mm
6.35
Sound Pressure
dBA
28
Heating
°C
25 - 50
Cooling
°C
-
5 - 20
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment.
• Altherma • Indoor units
21
• Indoor units • R-410A • EKHBH / EKHBX
2 2-2
Specifications ELECTRICAL SPECIFICATIONS
Electric heater
Type Power Supply
2 Current
2
Phase Frequency Voltage Running Current Zmax Zmax electric heater + booster heater (EKSWW* Models)
Electric heater
Type Power Supply
Current
Phase Frequency Voltage Running Current Zmax Zmax electric heater + booster heater (EKSWW* Models)
Electric heater
Type Power Supply
Current
Phase Frequency Voltage Running Current Zmax Zmax electric heater + booster heater (EKSWW* Models)
Electric heater
Type Power Supply
Current
Phase Frequency Voltage Running Current Zmax Zmax electric heater + booster heater (EKSWW* Models)
22
Hz V A
EKHBH007AC + EKHBH007AC + EKHBH007AC + EKHBX007AC + EKHBX007AC + EKHBX007AC + ERYQ005AC ERYQ006AC ERYQ007AC ERYQ005AC ERYQ006AC ERYQ007AC 3V3 1~ 50 230 13
List Text List Text
Hz V A List Text List Text
Hz V A List Text List Text
Hz V A List Text List Text
• Altherma • Indoor units
No requirements
0.24 + j0.15
6V3 1~ 50 230 26
0.24 + j0.15 0.16 + j0.10
6W1 3N~ 50 400 8.6 No requirements No requirements
6T1 3~ 50 230 15 Out of scope Out of scope
• Indoor units • R-410A • EKHBH / EKHBX
2 2-2
Specifications ELECTRICAL SPECIFICATIONS
Electric heater
Type Power Supply
Current
Phase Frequency Voltage Running Current Zmax Zmax electric heater + booster heater (EKSWW* Models)
Electric heater
Type Power Supply
Current
Phase Frequency Voltage Running Current Zmax Zmax electric heater + booster heater (EKSWW* Models)
Notes
Hz V A
EKHBH007AC + EKHBH007AC + EKHBH007AC + EKHBX007AC + EKHBX007AC + EKHBX007AC + ERYQ005AC ERYQ006AC ERYQ007AC ERYQ005AC ERYQ006AC ERYQ007AC 9W1 3N~ 50 400 13
List Text List Text
2 2
No requirements No requirements
9T1 3~ 50 230 23
Hz V A List Text List Text
Out of scope Out of scope
Optional electric heater has 2 capacity steps except for the 3V3 model which has only 1 capacity step. For 6W1 and 9W1 models, neutral line only required for optional booster heater power supply Model without optional back up heater is powered via outdoor unit
• Altherma • Indoor units
23
24
Back up heater 6kW 1∼230 V
Back up heater 6kW 3∼400 V + N
Back up heater 6kW 3∼230 V
Back up heater 9kW 3∼400 V + N
Back up heater 9kW 3∼230 V
6V3
6W1
6T1
9W1
9T1
• Altherma • Indoor units
Sanitary warm water tank 200 l 230 V
Sanitary warm water tank 300 l 230 V
Sanitary warm water tank 200 l 400 V
Sanitary warm water tank 300 l 400 V
Sanitary warm water tank 150 l 230 V
Sanitary warm water tank 200 l 230 V
Sanitary warm water tank 300 l 230 V
Wall bracket for EKSWW150V3
Option kit forUK EKSWWU150∼300V3
EKSWW200V3
EKSWW300V3
EKSWW200Z2
EKSWW300Z2
EKSWWU150V3
EKSWWU200V3
EKSWWU300V3
EKWBSWW150
EKUSWW
⎯ ⎯ ⎯ ⎯
⎯ ⎯ ⎯ ⎯
⎯
⎯
V
V V
V
V
⎯
⎯
V
V
V
V
V
V
V
⎯
V
⎯
V
EKHBH007AC6V3 EKHBX007AC6V3
Note: An EKHB (H/X) 007AC* indoor unit can only be connected to an outdoor unit ERYQ005∼007AC*
Sanitary warm water tank 150 l 230 V
EKSWW150V3
Available kits
Back up heater 3kW 1∼230 V
3V3
Available options
EKHBH007AC3V3 EKHBX007AC3V3
V
V
V
V
V
V
V
V
⎯
⎯
⎯
V
⎯
⎯
EKHBH007AC6W1 EKHBX007AC6W1
V
V
V
⎯
⎯
V
V
V
⎯
⎯
V
⎯
⎯
⎯
EKHBH007AC6T1 EKHBX007AC6T1
Number
V
V
V
V
V
V
V
V
⎯
V
⎯
⎯
⎯
⎯
EKHBH007AC9W1 EKHBX007AC9W1
V
V
V
⎯
⎯
V
V
V
V
⎯
⎯
⎯
⎯
⎯
EKHBH007AC9T1 EKHBX007AC9T1
3TW57559-5
Kit
Kit
Kit
Kit
Kit
Kit
Kit
Kit
Kit
Kit
Factory mounted
Factory mounted
Factory mounted
Factory mounted
Factory mounted
Factory mounted
Availability
3
Heating only model Reversible model
Description
2
Reference
Optional equipment for EKHB(H/X)007AC*
• Indoor units • R-410A • EKHBH / EKHBX
Options
3
• Indoor units • R-410A • EKHBH / EKHBX
4
Dimensional drawing & centre of gravity
4-1
Dimensional drawing
EKHBH-AC
2 4
Service door
Setup 1 Setup 2
A ≥ 200 ≥ 350
B ≥ 400 ≥ 200
1’’ female BSP
(Closed) 361 (Open) 553
1’’ male BSP
Min. 150
Min. 200
Centre of gravity j 1 Pump + switch for speed setting j 2 Remocon j 3 Water IN conection 1’’ M BSP j 4 Water OUT connection 1’’ M BSP j 5 Power supply intake (+ sanitary warm water tank) j 6 Drain / fill valve j 7 Air purge j 8 Expansion vessel + nipple j 9 Blow off valve j 10 Pressure gauge j 11 Water filter j 12 Suction pipe connection J15.9 flare connection j 13 Liquid pipe connection J6.35 flare connection j 14 Shut off valves (delivered with unit) j 15 Thermistor connection (+ sanitary warm water tank) j 16 Holes for fixation j 17 Blow off drain / drain of drainpan j 18 Switchbox connection terminals j 19 Wallbracket
Min. 100
Minimum space for service & ventilation
3TW57554-1A
EKHBX-AC
Minimum space for service & ventilation
1’’ female BSP
(Closed) 461 (Open) 653
1’’ male BSP
Dimensions wallbracket
Min. 150
Min. 200
Centre of gravity j 1 Pump + switch for speed setting j 2 Remocon j 3 Water IN conection 1’’ M BSP j 4 Water OUT connection 1’’ M BSP j 5 Power supply intake (+ sanitary warm water tank) j 6 Drain / fill valve j 7 Air purge j 8 Expansion vessel + nipple j 9 Blow off valve j 10 Pressure gauge j 11 Water filter j 12 Suction pipe connection J15.9 flare connection j 13 Liquid pipe connection J6.35 flare connection j 14 Shut off valves (delivered with unit) j 15 Thermistor connection (+ sanitary warm water tank) j 16 Holes for fixation j 17 Blow off drain / drain of drainpan j 18 Switchbox connection terminals j 19 Wallbracket
Min. 125
Service door
Setup 1 Setup 2
A ≥ 200 ≥ 350
B ≥ 400 ≥ 200
3TW57564-1A
• Altherma • Indoor units
25
• Indoor units • R-410A • EKHBH / EKHBX
5
Piping diagram
EKHB -AC
Water side
R4T R3T R2T R1T
2
Inlet water thermistor Refrigerant liquid side thermistor Outlet water backup heater thermistor Outlet water heat-exchanger thermistor
Field installation Filter Inlet Shut off valve
5 Refrigerant side
Safety valve Drain valve
Pressure gauge
Drain
Expansion vessel Cooling (EKHBX) Heating (EKHBX + EKHBH)
Option backup heater Drain valve
Field installation
Air purge
Flowswitch
Pump
Outlet Shut off valve
Overview Electric heater body Evaporator Condensor
Outdoor unit
Refr. out Refr. in
Water inlet Refrigerant side
Water side
Refr. in Water outlet Refr. out
O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe PSpinned pipe
26
• Altherma • Indoor units
3TW56715-1
• Indoor units • R-410A • EKHBH / EKHBX
6
Wiring diagram
6-1
Wiring diagram
EKHB007AC3V3 Power supply 230V 1N∼50Hz
Outdoor unit
Sanitary tank
>> See note 2 > See note 2
See note 2 > See note 2 typcial 2-persons usage pattern. Medium Daily demand up to 325 l -> typical 3 to 4 persons usage pattern. High Daily demand up to 550 l -> 4 to 6 persons usage pattern.
(2) Heat-up time: Definition: Heat-up time The time required to reheat the sanitary tank to 55°C after tapping a certain volume of hot water at 40°C. note: changing the field settings (see installation manual) can influence the heat-up time.
Tank 150L 200L 300L
Heat-up time for 150 L (bath) 60 60 50
Setpoint temp. (°C) 55 55 55
Heat-up time for 50 L (shower) 45 40 30
Conditions for testing: Ta = 7°CDB / 6°CWB, Troom = 20°C, Tstart = 10°C, outdoor unit type: ERYQ007
(3) Efficiency of sanitary hot water production: In the ALTHERMA by Daikin system both the heat-pump and the electric booster heater supply the energy to produce sanitary hot water. The higher the portion of energy supplied by the heat-pump, the more energy efficient the system is. Lowering the setpoint temperature increases the portion of energy supplied by the heat-pump and thus the efficiency of the system.
Heat-pump portion
Definition: Heat-pump portion Percentage of energy supplied by the heat-pump in the total energy need for sanitary hot water.
Setpoint temp. (°C) Conditions:
Real life condition Outdoor temperature Room temperature Outdoor unit type Tank type Field settings
Simulation of a daily usage based upon ′medium′ usage pattern. 7°CDB / 6°CWB 20°CDB ERYQ007 200l Default field settings (see installation manual).
4TW56719-3
34
• Altherma • Sanitary Hot Water
• Sanitary Hot Water • R-410A • EKSWW
4
Dimensional drawing & centre of gravity
4-1
Dimensional drawing
EKSWW j 1 Water mains in female 3/4’’ BSP j 2 Water mains out female 3/4’’ BSP j 3 Thermistor connection female 1/2’’ BSP j 4 Flow (from hydrobox) female 3/4’’ BSP j 5 Return (to hydrobox) female 3/4’’ BSP j 6 Switchbox j 7 Clixon j 8 Connection female 3/4’’ BSP j 9 Power entrance
3 4 Required service space around the tank
3TW56714-4A
• Altherma • Sanitary Hot Water
35
• Sanitary Hot Water • R-410A • EKSWW
5
Wiring diagram
5-1
External connection diagram Standard parts
Power supply Outdoor unit 3 core
Unit power supply: 230V + earth
For more details please check unit wiring diagram
X1M:L-N-Earth
Backup heater power supply (3/6/9kW): 400V or 230V + earth Optional power supply
Optional parts
3 core
5
4 core
3 or4 core
3
X2M:1-2-3-Earth Booster heater power supply (3kW): 400V or 230V + earth
Field supply X1M:9-10-11-Earth
Sanitary tank 2 way valve
2 core Q3L - Q1T Clixon Thermostat 2 way valve
Only for EKSWWU*V3 Power supply booster heater
5 core
4 core
230V or400V Q2L - Clixon booster heater
NO valve: NC valve:
2 core
Thermistor cable Note: min. distance to power cable = 3cm
2 core
2 core
R5T - Thermistor water temperature
Signal
Room thermostat A3P (optional)
X1M:7-8-Earth
2 way valve M2S (EKHBX Units) for cooling mode
3 way valve M3S (when EKSWW is installed) selection sanitary-floorheating
Indoor unit User interface
3TW56719-6A
36
• Altherma • Sanitary Hot Water